User’s Manual of GS-4210-16T2S_24T2S_16P2S_24P2S_48T4S
64
4.2.6 Log Management
The Managed Switch log management is provided here. The local logs allow you to configure and limit system messages that
are logged to flash or RAM memory. The default is for event levels 0 to 3 to be logged to flash and levels 0 to 6 to be logged to
RAM. The following table lists the event levels of the Managed Switch:
Level
Severity Name
Description
7
Debug
Debugging messages.
6
Informational
Informational messages only.
5
Notice
Normal but significant condition, such as cold start.
4
Warning
Warning conditions (e.g., return false, unexpected return).
3
Error
Error conditions (e.g., invalid input, default used).
2
Critical
Critical conditions (e.g., memory allocation, or free memory error - resource
exhausted).
1
Alert
Immediate action needed.
0
Emergency
System unusable.
4.2.6.1 Logging Service
The Managed Switch system local log information is provided here. The local Log screens in
Figure 4-2-12
and
Figure 4-2-13
appear.
Figure 4-2-12:
Logging Settings Page Screenshot
The page includes the following fields:
Object
Description
•
Logging Service
Enabled
: Enable logging service operation.
Disabled
: Disable logging service operation.