Generators
3-15-11
continued
CAUTION
The following buses are automatically load shed (no additional Cautions will
be shown) and the systems connected to them will be inoperative:
−
Generator 1 bus (Left rear CB panel)
−
Main bus (Right forward CB panel)
−
Avionic 2 bus (Right rear CB panel)
−
Non Essential Bus (Right front CB panel)
−
Cabin bus (Right rear CB panel)
−
Generator 2 bus (Right rear CB panel)
CAUTION
The following high current consumption systems are automatically load
shed:
−
Cabin heater
−
Under floor heater
−
RH windshield de-ice
−
Propeller de-ice
−
LH AOA plate heater
−
RH AOA plate heater
−
VCCS compressor
−
Footwarmer (optional system)
−
Logo lights (optional system)
Note
If further load reduction is desired to extend battery endurance beyond 33
minutes, consider manually switching off all exterior lights and if conditions
allow all ice protection.
---------- END -----------
Generator 1 Off
3-15-12
Generator 1 is OFF line and engine running.
1.
Systems MFD - ELECTRICAL
window........................................
Confirm the failure
Continued on next page
Section 3 - Emergency Procedures (EASA Approved)
Electrical System Failures
Pilot's Operating Handbook
Report No: 02406
Issue date: Mar 06, 2020
Page 3-15-6
12-C-A15-40-0315-00A-141A-A