Cockpit/Cabin Fire, Smoke or Fumes, Smoke
Evacuation
3-7-03
continued
9.
Aircraft.......................
Proceed to nearest Airfield
If smoke evacuation is required:
10. ACS EMER shut off... PULL
11. CABIN PRESSURE
switch........................
DUMP
When cabin pressure differential is zero:
12. DV window................
Open
13. VENT FANS..............
LOW
14. Fire Extinguisher.......
Use if required
As soon as time permits and source is known electrical:
15. Associated electrical
equipment..................
Off (circuit breakers)
Continued on next page