The phyCORE-LPC2292/94 on the phyCORE Carrier Board
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
85
+5 VDC
GND
≥
500 mA
Center Hole
1.3 mm
3.5 mm
--
+
Polarity:
Figure 20: Connecting the Supply Voltage at X1
Caution:
When using this function, the following jumper settings are not
allowed:
Jumper
Setting
Description
2 + 3
5 V as primary main supply voltage
for the phyCORE-LPC2292/94
JP9
open
phyCORE-LPC2292/94 not connected to
primary main supply voltage
1 + 2
3.3 V as secondary main supply voltage
for the phyCORE-LPC2292/94
JP16
open
phyCORE-LPC2292/94 not connected to
secondary main supply voltage
NOTE: This setting is correct if the module in its
minimum configuration without on-board CAN
transceivers is used.
Table 47:
JP9, JP16 Improper Jumper Settings for the Main Supply Voltages
Setting Jumper JP9 to position 2+3 configures a primary main power
supply to the phyCORE-LPC2292/94 of 5 V which could destroy the
module. Setting Jumper JP16 to position 1 + 2 configures a secondary
main power supply to the phyCORE-LPC2292/94 of 3.3 V which also
can damage the module. If Jumper JP9 and JP16 remain open, no
primary and secondary main power supply is connected to the
phyCORE-LPC2292/94. These jumper settings should therefore not
be used.
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...