Jumpers
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
21
Default Setting
Alternative Setting
J504
open
LAN_IRQ signal not
connected to an additional
10k pull-up resistor to
VDD_V3V3.
closed
LAN_IRQ signal is connected to
an additional 10k pull-up resistor
to VDD_V3V3
J505
open
IOS2 signal on SMSC LAN
91C111 connected with
internal pull-up to
VDD_V3V3, configuration
via predefined EEPROM
contents.
closed
IOS2 signal on SMSC LAN
91C111 connected to GND.
See
LAN91C111 data sheet for more
details
.
J506
open
IOS1 signal on SMSC LAN
91C111 connected with
internal pull-up to
VDD_V3V3, configuration
via predefined EEPROM
contents.
closed
IOS01 signal on SMSC LAN
91C111 connected to GND.
See
LAN91C111 data sheet for more
details
.
J507
open
IOS0 signal on SMSC LAN
91C111 connected with
internal pull-up to
VDD_V3V3, configuration
via predefined EEPROM
contents.
closed
IOS0 signal on SMSC LAN
91C111 connected to GND.
See
LAN91C111 data sheet for more
details
.
J508
open
ENEEP signal on SMSC
LAN 91C111 connected
with internal pull-up to
VDD_V3V3, configuration
via predefined EEPROM
contents.
closed
ENEEP signal on SMSC LAN
91C111 connected to GND.
See
LAN91C111 data sheet for more
details
.
J509
closed
LAN 91C111 nLNK pin tied
to GND, LINK_ON bit in
the EPH status register is set
to "1"
open
LAN 91C111 nLNK pin not
connected, LINK_ON bit in the
EPH status register is set to "0"
J600
1 + 2
P020 on the µC freely
available as standard I/O at
Molex pin X700A4
2 + 3
P020 used for enabling resp.
disabling the CAN transceiver
U605, connected to INH.
J601
1 + 2
P019 on the µC freely
available as standard I/O at
Molex pin X700C19
2 + 3
P019 used for enabling resp.
disabling the CAN transceiver
U606, connected to INH input.
J602
open
CAN_H1 signal generated
by CAN transceiver U605
(only if CAN transceiver
U605 populates the module).
closed
CAN_H1 signal directly
connected with µC port TD1 and
available as CAN TTL signal an
X700D21, for connection to
external CAN transceiver (only
in connection with unpopulated
U605).
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...