Pin
Description
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
15
Pin Row X700D
1D, 2D
VCC
-
Voltage input +3.3 VDC
3D, 9D, 14D, 19D,
24D, 29D, 34D, 39D
GND
--
Ground 0 V
4D, 5D, 7D
NC
-
Not connected.
These contacts should remain unconnected on the
target hardware side.
6D
VPD
O
Output of back-up voltage supply for buffering of
external components
8D
WDI
I
MAX6301 Watchdog input
10D
/RESIN
I
/RESET input of the phyCORE-LPC2292/94
11D
TxD1
O
Output of the second serial interface, TTL level
(alternative: port P08 of the microcontroller)
12D
RxD1
I
Input of the second serial interface, TTL level
(alternative: port P09 of the microcontroller)
13D
P011
I/O
Port P011 of the microcontroller
(see data sheet)
15D
P017
I/O
Port P017 of the microcontroller
(see data sheet)
16D
RxD0
I
Input of the first serial interface, TTL level
(alternative: port P0.1 of the microcontroller)
17D
TxD0
O
Output of the first serial interface, TTL level
(alternative: port P0.0 of the microcontroller)
18D
CAN_L2
I/O
Differential CANL line of the 2nd CAN transceiver
(alternativ P023 if J605 populated and U606 not
populated)
20D
CAN_L1
I/O
Differential CANL line of the first CAN transceiver
(alternativ P025 if J604 populated and U605 not
populated)
21D
CAN_H1
I/O
Differential CANH line of the first CAN transceiver
(alternativ TD1 if J602 populated and U605 not
populated)
22D
RxD0_ext
I
Input of the first serial interface, RS-232 level
23D
TxD0_ext
O
Output of the first serial interface, RS-232 level
25D
P116
I/O
Port P116 of the microcontroller
(see data sheet)
26D
P117
I/O
Port P117 of the microcontroller
(see data sheet)
27D
MISO0
I/O
Master-In/Slave-Out (for EEPROM)
28D
SCLK0
I/O
Clock input SPI interface (for EEPROM)
30D
P120
I/O
Port P120 of the microcontroller
(see data sheet)
(alternative: TRACESYNC of TRACE port)
31D
P121
I/O
Port P121 of the microcontroller
(see data sheet)
(alternative: PIPESTAT0 of TRACE port)
32D SDA I/O
I
2
C data line (for RTC)
33D
/INT_RTC
O
RTC interrupt output (from RTC)
35D
I
Positive Rx input of the Ethernet interface
36D
O
Positive Tx output of the Ethernet interface
37D P126
(RTCK)
I/O
Port P126 of the microcontroller
(see data sheet)
(alternative: RTCK of the JTAG interface)
38D P127
(TDO)
I/O
Port P127 of the microcontroller
(see data sheet)
(alternative: Data output JTAG interface)
40D P130
(TMS)
I/O
Port P130 of the microcontroller
(see data sheet)
(alternative: JTAG interface select input)
41D
P123
I/O
Port P123 of the microcontroller
(see data sheet)
(alternative: PIPESTAT2 of TRACE port)
42D
P124
I/O
Port P124 of the microcontroller
(see data sheet)
(alternative: TRACECLK of TRACE port)
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...