Jumpers
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
23
Default Setting
Alternative Setting
J610
closed
RTC (U604) SCL signal
connected to port P02 of the
µC. P02 is then no longer
available as standard I/O pin
at X700A47.
open
RTC SCL signal not connected
to the µC on the module,
external connection required (at
pin X700C31). P02 is available
as standard I/O pin at X700A47.
J611
closed
EEPROM (U607) /PCS0
signal connected to port P10
of the µC. P10 is then no
longer available as standard
I/O pin at X700B50.
open
EEPROM /PCS0 signal not
connected to the µC on the
module, external connection
required (at pin X700C26). P10
is available as standard I/O pin at
X700C13.
J612
closed
EEPROM (U607) MISO0
signal connected to port P05
of the µC. P05 is then no
longer available as standard
I/O pin at X700A49.
open
EEPROM MISO0 signal not
connected to the µC on the
module, external connection
required (at pin X700D27). P05
is available as standard I/O pin at
X700A49.
J613
closed
EEPROM (U607) MOSI0
signal connected to port P06
of the µC. P06 is then no
longer available as standard
I/O pin at X700A50.
open
EEPROM MOSI0 signal not
connected to the µC on the
module, external connection
required (at pin X700C28). P06
is available as standard I/O pin at
X700A50.
J614
closed
EEPROM (U607) SCLK0
signal connected to port P04
of the µC. P04 is then no
longer available as standard
I/O pin at X700B48.
open
EEPROM SCLK0 signal not
connected to the µC on the
module, external connection
required (at pin X700D28). P04
is available as standard I/O pin at
X700B48.
J615
1 + 2
Supply voltage for CAN
transceivers U605 and U606
(TLE6250V33) from VCC2
(5 V).
2 + 3
Supply voltage for CAN
transceivers U605 and U606
connected to VDD_V3V3
(3.3 V).
J616
closed
Pin 5 on CAN transceivers
U605 connected to 3.3 V
supply voltage (use only
with TLE6250V33 devices).
open
Pin 5 on CAN transceivers U605
not connected to 3.3 V supply
voltage (use only with other
CAN transceivers devices).
J617
closed
Pin 5 on CAN transceivers
U606 connected to 3.3 V
supply voltage (use only
with TLE6250V33 devices)
open
Pin 5 on CAN transceivers U606
not connected to 3.3 V supply
voltage (use only with other
CAN transceivers).
J618
open
VDD_V3V3 supply voltage
is switched via FET Q600A.
closed
VDD_V3V3 supply voltage
directly derived from VCC.
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...