Caution:
When using the DB-9 connector P2B as second CAN interface and the
CAN transceiver on the Carrier Board the following jumper settings
are not functional and could damage the module:
Jumper
Setting
Description
JP30
closed
Pin 8 at P2B is connected with TxD1_ext
from the phyCORE-LPC2292/94
1 + 2
Pin 2 at P2B is connected with RxD1_ext
from the phyCORE-LPC2292/94
JP33
2 + 4
Pin 2 at P2B is connected with CAN_L2/RD2 from the
on-board CAN transceiver on the
phyCORE-LPC2292/94
JP34
2 + 3
Pin 7 at P2B is connected with CAN_H2/TD2 from
the on-board CAN transceiver on the
phyCORE-LPC2292/94
1 + 2
Input at opto-coupler U6 on the Carrier Board is
connected to P1.21 of the phyCORE-LPC2292/94
2 + 3
Input at opto-coupler U6 on the Carrier Board is
connected to A23 of the phyCORE-LPC2292/94
JP14
open
Input at opto-coupler U6 on the Carrier Board
not connected
1 + 2
Output at opto-coupler U7 on the Carrier Board is
connected to P1.20 of the phyCORE-LPC2292/94
2 + 3
Output at opto-coupler U7 on the Carrier Board is
connected to A20 of the phyCORE-LPC2292/94
JP15
open
Output at opto-coupler U7 on the Carrier Board
not connected
JP13
1 + 2
Supply voltage for CAN transceiver and opto-coupler
on the Carrier Board derived from external source
(CAN bus) via on-board voltage regulator
JP29
closed
Supply voltage for on-board voltage regulator
from pin 9 of DB-9 connector P2A
JP39
see
CAN bus supply voltage reduction for CAN circuitry
Table 64:
Improper Jumper Settings for the CAN Plug P2B (CAN Transceiver
on the Carrier Board)
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...