phyCORE-LPC2292/94
42
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
3.20
J616, J617 CAN Transceiver VCC, Pin 5
These jumpers are used to connect the 3.3 V main supply voltage to
pin #5 on the TLE6250V33 CAN transceivers at U605 (J616) and
U606 (J617). If other CAN transceiver devices are used on the
phyCORE-LPC2292/94 these jumpers must remain open.
The following configurations are possible:
CAN Transceiver VCC, Pin 5
J616
J617
Pin 5 on CAN transceivers U605 connected
to 3.3 V supply voltage (use only with
TLE6250V33 devices).
closed* -
Pin 5 on CAN transceivers U605 not
connected to 3.3 V supply voltage (use only
with other CAN transceivers devices).
open -
Pin 5 on CAN transceivers U606 connected
to 3.3 V supply voltage (use only with
TLE6250V33 devices).
- closed*
Pin 5 on CAN transceivers U606 not
connected to 3.3 V supply voltage (use only
with other CAN transceivers devices).
- open
* = Default setting
Table 29:
J616, J617 CAN Transceiver VCC at Pin #5
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...