phyCORE-LPC2292/94
40
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
3.17
J608, J609, J610 I
2
C Interface
Jumpers J608, J609 and J610 are provided to connect the controller's
I
2
C interface to the on-board RTC and the phyCORE-connector. The
I
2
C signals SDA and SCL are available at pins X700C31 and
X700D32 if Jumpers J609 and J610 are closed. Jumper J608 connects
the RTC interrupt output to port P015. If all 3 jumpers remain open
the corresponding controller signals are available as standard I/O pins
at X700B47, X700A48 and X700B3.
The following configurations are possible:
Signal
Configuration
J608 J609 J610
Port pins P02, P03, P015
configured as I
2
C interface signals
closed* closed* closed*
Port pins P02, P03, P015 available
as standard I/O pins
open open open
* = Default setting
Table 26:
J608, J609, J610 I
2
C Interface Configuration
3.18
J611, J612, J613, J614 SPI0 Interface
Jumpers J611 through J614 connect the SPI0 interface signals of the
microcontroller to the on-board SPI bus. The on-board
EEPROM (U607) is connected to the SPI bus. If the jumpers remain
open, then the applicable controller pins P04, P05, P06 and P10, can
be used with their alternative functions at phyCORE-connector pins
X700B48, X700A49, X700A50 and X700C13. The SPI interface
signals are available at X700C26, X700C28, X700D27 and X700D28.
The following configurations are possible:
Function
J611 J612 J613 J614
on-board SPI0 bus connected
(SCLK0, /PCS0 MISO0, MOSI0)
closed* closed* closed* closed*
on-board SPI0 bus disconnected open open open open
* = Default setting
Table 27:
J611, J612, J613, J614 SPI Interface Signal Configuration
Summary of Contents for phyCORE-LPC2292/94
Page 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Page 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Page 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...