10
96
40
91 + 97
d
a
Ø 4
5 m
m
x
t
78
C2 Assembly of the Working Platforms
General
Cut the timber and platform decking
according to site-specific planning doc-
uments.
Working platforms for Version 2 and 3
can be pre-assembled up to the outer
Girder.
Mounting the Girders
Secure Girder (timber) to the truss gird-
er.
Components
10
Crossbar RCS 103
40
Girder (timber)
91
Bolt ISO 4017 M12 x 240-8.8
96
Nut ISO 4032 M12-8
97
Washer ISO 7093 200HV, A12
Assembly
1. Countersink Girder (40) min. 15 mm,
e.g. with a forstner drill Ø 45 mm, so
that the planking does not project on
the screw head.
For timbers more than 160 mm
thick, increase the countersink
depth.
Countersink depth x =
timber thickness d - 145 mm
2. Drill timber with Ø 14 mm.
3. Insert bolt M12 x 240 (91) with
washer (97) through the hole in the
timber and Crossbar, and tighten with
nut (96). For the bolt M12 x 240, the
maximum clamping length is
a = 220 mm.
(Fig. C1.07)