14
40
39.1
39
50 mm
59
B3 Corner Platforms
Internal Corners
For internal corners, PERI recommends
having a mitred arrangement.
Working platform is mitred accordingly.
Push Enclosure Beam (14) and Girder
(40) up to the mitre.
Assemble platform decking using mul-
ti-layer plywood sheeting in the mitred
area. Cover the gap between the mi-
tred enclosure elements. (Fig. B3.09)
Components
14
Enclosure Beam (timber)
39
Toeboard
39.1
Angle Bracket 90°
40
Girder (timber)
Fig. B3.09