82
80
81
Ø
a
d
d
c
L
49
B2 Planning the Units
Fig. B2.11
Fig. B2.12
Guardrails with Scaffold Tubes
Requirements:
Steel Scaffold Tubes (80) minimum
quality St37-2.
Dimensions Ø × t = 48.3 × 3.2 or 60.3
× 4.5 mm
Mounting:
Clamp A64 DIN 3570 (81)
Hex. Nut ISO 4032 M12-8 (82) (2x)
Mount Scaffold Tube on inner side,
with netting or tarpaulin also on the
outer side with spacing of a = 50 cm.
Max. cantilever d ≤ 0.5 · c
(Fig. B2.11)
At the ends and in the middle of the
span the Scaffold Tubes are to be
connected to each other using vertical
Scaffold Tubes or supported to prevent
any overloading.
Components
80
Steel Scaffold Tube Ø 48.3 x 3.2
81
Clamp A64 DIN 3570
82
Hex. Nut ISO 4032 M12-8
RCS P Climbing Protection Panel
Instructions for Assembly and Use – Standard Configuration
Summary of Contents for RCS P
Page 13: ...13 RCS P Climbing Protection Panel Instructions for Assembly and Use Standard Configuration...
Page 93: ...93 RCS P Climbing Protection Panel Instructions for Assembly and Use Standard Configuration...
Page 101: ...101 RCS P Climbing Protection Panel Instructions for Assembly and Use Standard Configuration...
Page 169: ...169...