Fig. B3.06
B3 Corner Platforms
Corner supports at the edge of the
building
For corner support, mount the Stopend
Slab Shoe RCS (48).
Realisation of the working platform in
the mitered area is carried out as previ-
ously described.
The corresponding Stopend Slab An-
chor (51 / 52) enables anchoring
through the column reinforcement.
Due to load transfer through the bond,
the Stopend Slab Anchor can be posi-
tioned very close to the slab edge (Fig.
B3.06)
See Section B4 "Anchoring on the Slab
Front Side".
Going below a lateral edge distance c1
for the anchoring is not advisable with-
out additional static proof. If necessary,
measure and arrange edging reinforce-
ment in the slab.
Anchoring applicable for c1: Screw-On
Cone,
Cimbing Cone 320 mm.