![background image](http://html1.mh-extra.com/html/patton-electronics/smartnode-series/smartnode-series_software-configuration-manual_4048643226.webp)
RBS configuration task list
226
SmartWare Software Configuration Guide
20 • RBS configuration
Mode:
Operator execution
Mode:
Operator execution
RBS Configuration Examples
Example:
Configuring RBS Ground Start on a E1T1 port
port e1t1 0 0
port-type t1
clock slave
linecode b8zs
framing esf
encapsulation rbs
rbs
protocol ground-start subscriber
encapsulation cc-rbs
bind interface RBS00 switch
port e1t1 0 0
no shutdown
Example:
Configuring different RBS protocols with a Channel Group on an E1T1 port
port e1t1 0 0
port-type t1
clock slave
linecode b8zs
framing esf
encapsulation channelized
channel-group RBS_GROUP_1_8
timeslots 1-8
encapsulation rbs
rbs
protocol eam-wink-start
encapsulation cc-rbs
bind interface RBS00_1_8 switch
channel-group RBS_GROUP_9_16
timeslots 9-16
encapsulation rbs
rbs
protocol eam-immediate-start
encapsulation cc-rbs
bind interface RBS00_9_16 switch
Step
Command
Purpose
1
node
#[no] debug cas {event | error}
Enables/Disables CAS event/error monitor
Step
Command
Purpose
1
node
#[no] debug rbs {event | error}
Enables/Disables RBS event/error monitor