4.17 System Size Selector
Pressing this button causes the control system scroll through the available system recovery sizes within
Coral Sea product line, each time the button is pressed the system will increment to the next available
size as listed here: 2800, 3600, 4200, 5200, 6200 & 6800. Once the maximum system size has been
reached pressing the system size selection button again will cause the system to return the beginning of
the list.
4.18 Special Level Control
Some control systems are specially requested with tank full and tank empty level control abilities, if your
control system has been built to accommodate these special functions, you may enable and disable this
function by pressing this button. AS you press the button the text within the button will change to
reflect the current state of the feature.
4.19 Min Product (GPM)
* Please note: *
Entering data into this field is only permitted if the user has selected ‘Force Manual Settings’,
confirmation that this mode is enabled is given by the ‘System Size Notification Window’. Once manual
settings are enabled the text within the window will change from a standard system production size to
‘MANUAL MODE’. To enter manual mode, press the ‘Manual System Production Variable Settings’
button.
This value determines what minimum permeate flow rates the controller should expect to see during
normal operation, if the controller sees permeate flow rates drop below this level consistently for 60
seconds it will alert you by raising a performance warning (See Performance Warning Messages)
indicating the detected problem, the water maker will not shut down and will continue to function at
these lower permeate flow rates. However attempts should be made to discover why permeate flow
rates have fallen.
Normal values are automatically entered here as system sizes are adjusted using the ‘System Size
Selector’ button. However in manual mode any value can be entered here.
Coral Sea Owner's Manual
Summary of Contents for Coral Sea
Page 3: ...SECTION 1 SYSTEM DESCRIPTION Coral Sea Owner s Manual...
Page 14: ...SECTION 2 PRE INSTALLATION NOTES Coral Sea Owner s Manual...
Page 25: ...SECTION 3 ELECTRICAL INFORMATION Coral Sea Owner s Manual...
Page 28: ...SECTION 4 INSTALLATION REQUIREMENTS Coral Sea Owner s Manual...
Page 35: ...SECTION 5 OPERATIONS MANUAL Coral Sea Owner s Manual...
Page 36: ...Operation THIS PAGE INTENTIONALLY LEFT BLANK Coral Sea Owner s Manual...
Page 166: ...Intentionally Left Blank Coral Sea Owner s Manual...
Page 167: ...SECTION 6 R O MEMBRANE INSTALL CARE Coral Sea Owner s Manual...
Page 193: ...SECTION 7 MAINTENANCE AND REPAIR Coral Sea Owner s Manual...
Page 194: ...Maintenance Coral Sea Owner s Manual...
Page 203: ...SECTION 8 COMPONENT USER MANUALS Coral Sea Owner s Manual...
Page 204: ...Page Intentionally Left Blank Coral Sea Owner s Manual...
Page 215: ...SECTION 9 DRAWING PULL OUTS Coral Sea Owner s Manual...
Page 216: ...Page Left Intentionally Blank Coral Sea Owner s Manual...
Page 247: ...SECTION 10 SPARE PARTS LIST Coral Sea Owner s Manual...