4.13 Domestic Max. Salinity Level (uS/cm):
This value stated in uS/cm determines at what product water conductivity level the system will activate
the diversion valve and UV sterilizer (if fitted). Once the product water measured conductivity drops
below the number inputted here, the water maker deems the water as acceptable.
Typical values entered here are 1200 uS/cm in all applications
4.14 Domestic Min. Salinity Level (uS/cm):
This setting allows you to determine what minimum salinity level from the salinity probe will be
accepted. Domestic systems cannot produce product water with salinity lower than the value entered
here, therefore any readings below this value causes the water maker control system to reject the
salinity probe input under the suspicion that the salinity probe has been removed from the system pipe
work and is currently sitting in air.
Typical values entered here are 100 in domestic water applications
4.15 PPM Conversion Factor:
Europe and the US use different scaling factors when converting uS/cm in to PPM. Within the US a
scaling factor of approximately 0.5 is used, within Europe a factor of 0.67 is used. Press on the
conversion factor you desire, once set the selected conversion factor button will remain depressed.
Changing this scaling factor results in a different bar and numbering system on the product water
salinity monitoring page when ‘PPM’ is selected as the preferred viewing unit.
4.16 System Time and Date:
This will allow you to change the time and date stored within the touch screen. To access this high level
editing screen a password is required. Contact Parker Sea Recovery for further details
To exit the system settings screens you must press the “Save Settings’ button located in the lower right
hand corner of the second settings screen, even if you have not applied any changes to the system
settings, this button must be pressed to exit the settings screen. Failure to do so will result in an
automatic save after 60 seconds of inactivity.
Coral Sea Owner's Manual
Summary of Contents for Coral Sea
Page 3: ...SECTION 1 SYSTEM DESCRIPTION Coral Sea Owner s Manual...
Page 14: ...SECTION 2 PRE INSTALLATION NOTES Coral Sea Owner s Manual...
Page 25: ...SECTION 3 ELECTRICAL INFORMATION Coral Sea Owner s Manual...
Page 28: ...SECTION 4 INSTALLATION REQUIREMENTS Coral Sea Owner s Manual...
Page 35: ...SECTION 5 OPERATIONS MANUAL Coral Sea Owner s Manual...
Page 36: ...Operation THIS PAGE INTENTIONALLY LEFT BLANK Coral Sea Owner s Manual...
Page 166: ...Intentionally Left Blank Coral Sea Owner s Manual...
Page 167: ...SECTION 6 R O MEMBRANE INSTALL CARE Coral Sea Owner s Manual...
Page 193: ...SECTION 7 MAINTENANCE AND REPAIR Coral Sea Owner s Manual...
Page 194: ...Maintenance Coral Sea Owner s Manual...
Page 203: ...SECTION 8 COMPONENT USER MANUALS Coral Sea Owner s Manual...
Page 204: ...Page Intentionally Left Blank Coral Sea Owner s Manual...
Page 215: ...SECTION 9 DRAWING PULL OUTS Coral Sea Owner s Manual...
Page 216: ...Page Left Intentionally Blank Coral Sea Owner s Manual...
Page 247: ...SECTION 10 SPARE PARTS LIST Coral Sea Owner s Manual...