Coral Sea Vertical 6800
Page 2-8
Pre-installa
tion
shutdown the System.
3. Brine discharge line atmospheric check valve allows
for natural drainage of the discharge line without
creating a vacuum in the line.
4. Brine discharge outlet fl ange connection is the
connection point for the brine discharge line back to
the feed source.
F. PRODUCT WATER MONITORING SUBSYSTEM:
This section of the System gives a visual indication of the
clarity and quantity of product water being produced. By
correlating the quantity of product water produced to the
System operating pressure, temperature and salinity of
the system feed water the user can establish whether the
SRC R.O. membrane element requires cleaning. This also
allows the user to estimate the running time required to fi ll
or refi ll the product water storage tank(s) or cistern(s).
Post fi ltration of the SRC System, is the fi nal step in
product water quality control. The type and quantity of
post fi ltration required is dependent on the quality of the
System feed water and desired quality or conditions of
the product water. By the time the product water reaches
the post fi ltration stage, the R.O. membrane element has
removed most of the dissolved solids present in the feed
water.
The Sea Recovery exclusive temperature compensated
electronic subsystem has rejected any high salinity
product water, so the water is potable from a salinity
standpoint. The post fi ltration subsystem is designed to
limit unpleasant odor, taste, and biological matter such
as bacteria, virus, and other microorganisms which may
have passed through the R.O. Membrane Element and
would therefore be present in the product water. Optional
post treatment and post fi ltration, such as pH adjustment,
hardness adjustment, biological control and others may be
added to the product water line if specifi c conditions are
required by the owner.
1. Product water test taps located at each end of the
R.O. membrane element pressure vessel assemblies
allow the user to draw water samples from each of
the individual R.O. membrane elements.
2. Product water manifold is designed to collect all
product water produced by the R.O. Membrane
Elements and routes the combined production on to
the Product Water Flow Meter.
3. Product water line check valve is vented to the
atmosphere for relief of vacuum during the condition
of natural osmosis occurring as a result of power
failure during normal pressurized operation, and,
while the System is in operation, but not pressurized.
4. Potable product water line check valve prevents
foreign chemical intrusion into the product water line
from the product water storage tank or cistern.
5. Temperature compensated salinity probe is directly
connected to the salinity controller, and sends a
continuous signal to it. It electrically determines
whether the salinity content of the product water is
acceptable. This unique salinity probe compensates
automatically for water temperature variations. A
salinity probe must be temperature compensated
in order to provide accurate readings, and protect
the health of the individuals consuming the product
water.
6. Gallon/Liter per minute product water fl ow meter has
a fl ow-through design which allows it to measure the
rate of product water progress from the membrane
toward the product water storage tank. This fl ow
meter is essential for plotting records of membrane
performance for maintenance purposes.
7. Product water line pressure gauge registers the
pressure on the product water line and assists the
operator in diagnosing any line blockages. The
product water line must be kept free and clear of any
blockages.
8. Three-way diversion actuator valve is made of solid
PVC and functions according to signals received
from the salinity controller. After the controller has
determined, from the temperature compensated
salinity probe, that potable (drinkable) water is
being produced, the controller energizes the valve
to the “Potable” position. If the product water being
produced is “Unpotable” then the controller energizes
the valve to the “Unpotable” (discharge) position.
9. Potable product water outlet fl ange connection is
provided at the skid edge for potable product routing
into the booster pump skid edge where the post
fi ltration components are located.
10. Potable product water outlet fl ange connection at the
booster pump skid edge for inter connection of the
System product water outlet and booster pumps post
fi ltration section.
11. Hose wash down valve and connection is supplied to
the System skid edge allowing the operator to utilize
the product water being produced by the System for
wash down and fi lling of the pretreatment or cleaning
tanks.
12. Product water charcoal fi lter is designed to assist in
the removal of unpleasant odors from the product
water. A second charcoal fi lter may be added
between the product water storage tank or cistern
and the point of use. This would be desirable to
remove impurities, sediment particles, or the taste of
chlorine, all of which may be present in the product
storage tank or cistern, due to sources other than the
Coral Sea Owner's Manual
Summary of Contents for Coral Sea
Page 3: ...SECTION 1 SYSTEM DESCRIPTION Coral Sea Owner s Manual...
Page 14: ...SECTION 2 PRE INSTALLATION NOTES Coral Sea Owner s Manual...
Page 25: ...SECTION 3 ELECTRICAL INFORMATION Coral Sea Owner s Manual...
Page 28: ...SECTION 4 INSTALLATION REQUIREMENTS Coral Sea Owner s Manual...
Page 35: ...SECTION 5 OPERATIONS MANUAL Coral Sea Owner s Manual...
Page 36: ...Operation THIS PAGE INTENTIONALLY LEFT BLANK Coral Sea Owner s Manual...
Page 166: ...Intentionally Left Blank Coral Sea Owner s Manual...
Page 167: ...SECTION 6 R O MEMBRANE INSTALL CARE Coral Sea Owner s Manual...
Page 193: ...SECTION 7 MAINTENANCE AND REPAIR Coral Sea Owner s Manual...
Page 194: ...Maintenance Coral Sea Owner s Manual...
Page 203: ...SECTION 8 COMPONENT USER MANUALS Coral Sea Owner s Manual...
Page 204: ...Page Intentionally Left Blank Coral Sea Owner s Manual...
Page 215: ...SECTION 9 DRAWING PULL OUTS Coral Sea Owner s Manual...
Page 216: ...Page Left Intentionally Blank Coral Sea Owner s Manual...
Page 247: ...SECTION 10 SPARE PARTS LIST Coral Sea Owner s Manual...