Coral Sea Vertical 6800
Page 2-10
Pre-installa
tion
13. Flow meter - FL 1003 4-40 gpm (15.1-151 lpm)
measures the combined rate of the backwash water
through the Media Filters.
K. ELECTRICAL CONTROLLER PANEL
1. Contactor, High Pressure Pump Motor Starter is rated
for a maximum of 10 horsepower.
1. Salinity Controller is the central point of connection
for all electrical lines in the System. The controller
monitors the salt content of the product water (by
means of the salinity probe), and signals the PVC
three-way diversion actuator valve, when potable
water is being produced. The PVC three-way
diversion actuator valve, motors, U.V. sterilizer, and
remote monitor are all directly connected to and
governed by the Salinity Controller.
Optional electrical equipment is also available such
as soft motor starters and disconnect switches.
Consult Sea Recovery’s Application Engineering
Department.
J. FRONT CONTROL PANEL
1. Pressure gauge - PI 1000 - 30 in. Hg to 70 psi (-1 to
4.8 bar) registers booster pump inlet vacuum suction
or pressure.
2. Pressure gauge -PI 1001 0 to 160 psi (0 to 11 bar)
registers booster pump outlet pressure, which is also
inlet pressure to the Media Filter.
3. & 4. Pressure gauges -PI 1002 0 to 60 psi (0 to 11
bar) registers combined Media Filter outlet pressures
as well as the 20 micron cartridge pre-fi lter inlet
pressures.
5. & 6. Pressure gauges - PI 1003 0 to 160 psi (0 to 11)
registers combined 20 micron cartridge pre-fi lter
outlet pressures as well as the 5 micron cartridge
pre-fi lter inlet pressures.
7. Pressure gauge - PI 1004 0 to 160 psi (0 to 11 bar)
registers combined 5 micron cartridge pre-fi lter outlet
pressure as well as the high pressure pump inlet
pressure.
8. Pressure gauge - PI 1005 0-2000 psi (0-138 bar)
registers outlet pressure from the high pressure
pump as well as the inlet pressure to the R.O.
membrane vessel assemblies.
9. Pressure gauge - PI 1006 0-2000 psi (0-138 bar)
registers outlet pressure from the R.O. membrane
vessel assemblies as well as the inlet pressure to the
back pressure regulator.
10. Pressure gauge - PI 1007 0-160 psi (0-11 bar)
registers the combined outlet pressure from the
product water port of the R.O. membrane vessels
(product water line pressure).
11. Pressure gauge - PI 1008 0-160 psi (0-11 bar)
registers the pressure present in the brine discharge
line.
12. Flow meter - FL 1001 10-80 gpm (37.8-302 lpm)
measures the rate of the feed water progress through
the System.
Coral Sea Owner's Manual
Summary of Contents for Coral Sea
Page 3: ...SECTION 1 SYSTEM DESCRIPTION Coral Sea Owner s Manual...
Page 14: ...SECTION 2 PRE INSTALLATION NOTES Coral Sea Owner s Manual...
Page 25: ...SECTION 3 ELECTRICAL INFORMATION Coral Sea Owner s Manual...
Page 28: ...SECTION 4 INSTALLATION REQUIREMENTS Coral Sea Owner s Manual...
Page 35: ...SECTION 5 OPERATIONS MANUAL Coral Sea Owner s Manual...
Page 36: ...Operation THIS PAGE INTENTIONALLY LEFT BLANK Coral Sea Owner s Manual...
Page 166: ...Intentionally Left Blank Coral Sea Owner s Manual...
Page 167: ...SECTION 6 R O MEMBRANE INSTALL CARE Coral Sea Owner s Manual...
Page 193: ...SECTION 7 MAINTENANCE AND REPAIR Coral Sea Owner s Manual...
Page 194: ...Maintenance Coral Sea Owner s Manual...
Page 203: ...SECTION 8 COMPONENT USER MANUALS Coral Sea Owner s Manual...
Page 204: ...Page Intentionally Left Blank Coral Sea Owner s Manual...
Page 215: ...SECTION 9 DRAWING PULL OUTS Coral Sea Owner s Manual...
Page 216: ...Page Left Intentionally Blank Coral Sea Owner s Manual...
Page 247: ...SECTION 10 SPARE PARTS LIST Coral Sea Owner s Manual...