CONTROL SYSTEM OPERATIONS MANUAL
]
May, 2015
Project:
Doc:
Version:
Parker Sea Recovery Coral Sea
1010016
01c
Document Name:
Author:
Page:
Control System Operations Manual
AGE
Page 70 of 129
45
Manual Start Failed. Low Pressure
Sensor Fault Detected
The operator attempted to run the system in manual
mode but during the start-up procedure the control
system detected a fault with the low pressure sensor
(PT-1004) and the manual run was aborted to protect
the system from damage. Enter the system status
message center for further details of the fault. Rectify
the fault or override the sensor before continuing.
46
Manual Start Failed. High Pressure
Sensor Fault Detected
The operator attempted to run the system in manual
mode but during the start-up procedure the control
system detected a fault with the high pressure sensor
(PT-1005) and the manual run was aborted to protect
the system from damage. Enter the system status
message center for further details of the fault. Rectify
the fault or override the sensor before continuing.
47
Domestic Diversion Valve Position
Feedback Lost
The control system has lost all position feedback from
the product diversion valve. Check valve wiring for
breaks or snags, check 5 x 20mm fuses within the
control panel for failures (indicated by red light)
48
Domestic Diversion Valve Did Not
Attempt To Open
The control system commanded the product diversion
valve to open but the valve did not respond to the
command at all. Check that the valve is switch to
'Auto' and that all power wiring is free from breaks or
snags. Check 5 x 20mm fuses within the control panel
for failures (indicated by red light)
49
Domestic Diversion Valve Failed
To Complete Open Motion
The control system commanded the product diversion
valve to open. The valve responded to the command
but failed to open fully in the time allowed. Probable
cause of failure is either power loss to the valve, or a
worn and failing actuator. Check 5 x 20 mm fuses
within control panel for failures (indicated by red light)
50
Domestic Diversion Valve Opening
Fault
This fault indicator is usually raised along with either a
failure to respond to open command fault, or an open
command motion failed to complete.
51
Domestic Diversion Valve Closing
Fault
This fault indicator is usually raised along with either a
failure to respond to close command fault, or a close
command motion failed to complete.
Coral Sea Owner's Manual
Summary of Contents for Coral Sea
Page 3: ...SECTION 1 SYSTEM DESCRIPTION Coral Sea Owner s Manual...
Page 14: ...SECTION 2 PRE INSTALLATION NOTES Coral Sea Owner s Manual...
Page 25: ...SECTION 3 ELECTRICAL INFORMATION Coral Sea Owner s Manual...
Page 28: ...SECTION 4 INSTALLATION REQUIREMENTS Coral Sea Owner s Manual...
Page 35: ...SECTION 5 OPERATIONS MANUAL Coral Sea Owner s Manual...
Page 36: ...Operation THIS PAGE INTENTIONALLY LEFT BLANK Coral Sea Owner s Manual...
Page 166: ...Intentionally Left Blank Coral Sea Owner s Manual...
Page 167: ...SECTION 6 R O MEMBRANE INSTALL CARE Coral Sea Owner s Manual...
Page 193: ...SECTION 7 MAINTENANCE AND REPAIR Coral Sea Owner s Manual...
Page 194: ...Maintenance Coral Sea Owner s Manual...
Page 203: ...SECTION 8 COMPONENT USER MANUALS Coral Sea Owner s Manual...
Page 204: ...Page Intentionally Left Blank Coral Sea Owner s Manual...
Page 215: ...SECTION 9 DRAWING PULL OUTS Coral Sea Owner s Manual...
Page 216: ...Page Left Intentionally Blank Coral Sea Owner s Manual...
Page 247: ...SECTION 10 SPARE PARTS LIST Coral Sea Owner s Manual...