background image

3 Installation

3-14

NetPath 100 User’s Manual - Installation Guide

980-001-0210K

 November 

2000

Console Cabling

In Console Mode, the AUX 2 port is configured as a VT-100 interface, 9.6Kbps, asyn-
chronous, 8 data bits, one start bit, one stop bit, and no parity.

The Console Mode is enabled on the AUX 2 port when the “Console” Pin (#5) on the 
AUX 2 connector is asserted (connect the Console pin to the terminal’s DTR). Use ca-
ble assembly # 135-007-0400 for DB-25 connector, cable assembly # 135-000-0464 
for DB-9 connector, or per pinout shown in Figure 3-5.

NOTE:  When AUX 2 Console Mode is enabled, the internal Modem is disabled.

Figure 3-5 AUX 2 Port, Console Cabling

Modem Line 
Connection

Use cable assembly # 135-007-7200, or per pinout shown in Table 3-10.

Connections 
Completed

All connections to basic NetPath 100 are now completed.

Proceed to the Configuration in section 4 Operation of this manual.

3

4

5

6

8 -P in

M o d u la r

A U X   2   P o rt

C o n n e cto r

C o n so le

G N D

R D

T D

3

7

20

2

8

6

4

5

D B -2 5 F

V T -1 0 0   T e rm in a l

C o n n e cto r

D S R

D C D

R D

T D

D T R

G N D

R T S

C T S

D irect  C onnect  C onsole

C able Adapter

1

8

AU X

C onnector

Table 3-10 Modem Line Pinout, RJ11C Connector

Pin

Description

1,2

No Connection

3

R  (Ring)

4

T  (Tip)

5,6

No Connection

1

4

D ia l

L in e

Summary of Contents for FrameSaver NP 100

Page 1: ...Frame Relay Digital Service Unit User s Manual Installation Guide Pub No 980 001 0210K November 2000 The information in this manual pertains to Base Software Revision 10 01 XX...

Page 2: ...se this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to make changes in existing products or to notify any person of such revisio...

Page 3: ...roduct where the cord will be abused by persons walking on it 9 Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock 10 Never push objects of any k...

Page 4: ...l 2 1 ISDN Adapter Option 2 2 ISDN Backup 2 2 ISDN Bandwidth On Demand 2 3 NetPath 100 2 4 Power Control Unit Option 2 5 Operating Features 2 6 Management Access 2 6 Password Security 2 6 System Scree...

Page 5: ...4 2 DIP Switch Configurations 4 2 CSU Parameters 4 3 Time Slot Configuration 4 4 WAN DLCI Address 4 4 Establish Management Session 4 6 Login 4 6 Block Mode 4 7 Logout 4 7 Screen Format 4 7 Help Text...

Page 6: ...e Download 5 34 DTE Dialing Using NetPath 100 AUX Ports Internal Modem 5 35 Management Access 5 36 Dial In 5 36 Direct Connect AUX 2 5 36 SNMP SET Command 5 36 6 Options ISDN Adapter Option 6 3 Instal...

Page 7: ...ide 980 001 0210K November 2000 Appendix Fault Test Screen Displays A 1 CSU Fault A 2 Frame Manager Fault A 2 ISDN Backup A 3 ISDN Demand A 4 Line n Bn ISDN A 5 Modem Status Fault A 8 Network Set Loop...

Page 8: ...igure 3 3 NetPath 100 Power Connection 3 4 Figure 3 4 Power Control Unit Connections 3 6 Figure 3 5 AUX 2 Port Console Cabling 3 14 4 Operation Figure 4 1 Configuration DIP Switches 4 2 Figure 4 2 Set...

Page 9: ...rotocol Monitor Statistics Summary Screen 5 22 Figure 5 16 Protocol Monitor Statistics History 5 24 Figure 5 17 Tx Conversation Mode Ranked by Octet 5 26 Figure 5 18 Rx Conversation Mode Ranked by Oct...

Page 10: ...8 Pin Modular Connector 3 13 Table 3 9 AUX 2 Pinout 8 Pin Modular Connector 3 13 Table 3 10 Modem Line Pinout RJ11C Connector 3 14 Table 3 11 NetPath 100 General Specifications 3 15 Table 3 12 Model 4...

Page 11: ...dix Table A 1 CSU Fault A 2 Table A 2 Frame Manager Fault A 2 Table A 3 ISDN Backup User Circuit A 3 Table A 4 ISDN On Demand Port A 4 Table A 5 Line n Bn ISDN A 5 Table A 6 ISDN Connection Cause Code...

Page 12: ...t of this manual includes several aids to help the user locate and use infor mation quickly At the beginning of this manual there is a Table of Contents which provides an outline and quick overview of...

Page 13: ...E THIS EQUIPMENT SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL ATTENTION CET APPAREIL NE CONTIENT AUCUN EL MENT QUE L UTILISATEUR PUISSE R PARER CONFEIR LA MAINTENACE UN PERSONNEL TECHNIQUE...

Page 14: ...hould be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance f...

Page 15: ...t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone com...

Page 16: ...will have to be re stored via remote management accessed reconfiguration Specific configuration items affected are Delay monitoring for all PVCs will be turned OFF if previously configured for Delay...

Page 17: ...OFF if previously configured for Delay monitoring Protocol Monitoring selections may be mis mapped different protocols selected if previously configured for Protocol monitoring Downloading Revision 8...

Page 18: ...affected are Delay monitoring for all PVCs will be turned OFF if previously configured for Delay monitoring Protocol Monitoring selections may be mis mapped different protocols selected if previously...

Page 19: ...OFF if previously configured for Delay monitoring Protocol Monitoring selections may be mis mapped different protocols selected if previously configured for Protocol monitoring Rev 3 01 xx from Rev 2...

Page 20: ...the Customer Data and FSU management NOTE NetPath 100 is transparent to SVCs Switched Virtual Circuits The NetPath 100 can have up to two IP Addresses for management One IP Address allows it to commu...

Page 21: ...e port or the frame switch manager may reroute the original PVCs to the Backup Frame Switch It is also possible to bypass the entire Frame Relay Network and initiate backup to a pool of ports on an al...

Page 22: ...onfiguration showing simultaneous Bandwidth On Demand and Backup connections is shown in Figure 2 3 Figure 2 3 Typical Simultaneous Bandwidth On Demand Configuration The bandwidth on demand process is...

Page 23: ...e basic NetPath 100 are shown in Figure 2 4 and Figure 2 5 Detailed descriptions of the NetPath 100 indicators and controls are provided in sec tion 5 Diagnostics of this manual Connector and pinout d...

Page 24: ...N SWITCHED AC OUT and Control Power The PCU responds to an operator command to interrupt power to the connected device for a duration of one 1 to 300 seconds When commanded the PCU interrupts both the...

Page 25: ...cs information Password Security Security is provided through five levels of password protected access Level 1 System Access Password Allows access to system login via User Access Passwords Levels 2 5...

Page 26: ...either by NetPath 100 s dedicated network facing management PVC as shown in Figure 2 1 or by the Tunneled management channel on a network facing Payload PVC as shown in Figure 2 7 Figure 2 7 Tunneled...

Page 27: ...E facing dedicated PVC management channel These optional management paths are shown in Figure 2 8 Figure 2 8 Payload CPE Management Customer Data Center IP Over Fram e Customer Mgmt PVCs Customer LAN...

Page 28: ...ss is associated with the network facing dedicated PVC or Tunneled payload PVC In this mode there may be a secondary IP Address The secondary IP Address can be associated with a specified payload PVC...

Page 29: ...n ager especially if static routing and dedicated backup ports are utilized The setting learning of these additional IP Addresses is described in detail in Section 4 Config uration in this manual NetP...

Page 30: ...the issuance of unique Traps Traps are issued either in band or dial out out of band via the on board modem depending on the specific fault detected Section 5 Diagnostics of this manual lists the MIB...

Page 31: ...Director Figure 2 9 Modem Call Director Block Diagram On incoming calls the modem to interface assignment is made based on the DTMF code detected after the NetPath 100 line interface goes off hook an...

Page 32: ...ing space may overheat the unit and void the warranty 1 Before unpacking ensure that the factory carton does not show any signs of damage If it does contact the freight carrier immediately 2 Unpack th...

Page 33: ...r the wall s surface material i e wood screws for wooden surfaces expansion fasteners for gypsum wall board etc The Power Control Unit may also be placed or mounted on a table top shelf or floor near...

Page 34: ...utput Connectors and Control Specifications Connectors Description Power Connector Internal Power Supply with IEC 320 power cord Control Output 4 pin keyed connector to control Model 467 Power Control...

Page 35: ...outlet 3 Once connected the NetPath 100 will go through the following normal power up sequence Basic NetPath 100 a The POWER LED will light immediately and stay on b The READY LED will flash while th...

Page 36: ...gnored at this time If the LED indications are not as described above refer to section 5 Diagnostics of this manual If operation looks normal unplug the NetPath 100 and make the required data input ou...

Page 37: ...ct the other end to the Control Output connector on the rear panel of the NetPath 100 shown in Figure 3 3 C Verify that the proper voltage is present at the outlet to be used 125 VAC 50 60 Hz If the o...

Page 38: ...ble 3 2 Data Port Interface Cable Codes The NetPath 100 Data Port DTE supports four electrical interface types ITU V 35 EIA 530 EIA 530 A and ITU X 21 NS The Data Port connector on the back of the Net...

Page 39: ...A Output 2 NC 24 DTR A Input 3 NC 25 TC A Output 4 RTS s Input 26 CBC A N A 5 CTS s Output 27 RC A Output 6 DSR s Output 28 CBC B N A 7 Sig Gnd N A 29 TCE A Input 8 DCD s Output 30 CBC C N A 9 DTR s I...

Page 40: ...C 4 RTS s Input W 44 TCE B Input D 5 CTS s Output X 42 RC B Output E 6 DSR s Output Y 25 TC A Output F 8 DCD s Output Z G AA 40 TC B Output H 9 DTR s Input BB I CC J DD K EE L FF M GG N HH O II P 17 T...

Page 41: ...Output 16 33 RD B Output 4 19 RTS A Input 17 27 RC A Output 5 20 CTS A Output 18 6 21 DSR A Output 19 34 RTS B Input 7 22 Sig Gnd N A 20 24 DTR A Input 8 23 DCD A Output 21 9 42 RC B Output 22 36 DSR...

Page 42: ...put 3 18 RD A Output 16 33 RD B Output 4 19 RTS A Input 17 27 RC A Output 5 20 CTS A Output 18 6 6 DSR s Output 19 34 RTS B Input 7 22 Sig Gnd N A 20 9 DTR s Input 8 23 DCD A Output 21 9 42 RC B Outpu...

Page 43: ...Inc CAUTION Use caution when connecting to an AUX Port AUX Port connectors are similar to the connector for the T1 Line Accidental connection to either of the AUX Ports with the T1 Line may damage th...

Page 44: ...drive both RLSD and DSR leads within the adapter Table 3 9 AUX 2 Pinout 8 Pin Modular Connector Pin Signal Direction 1 CTS Output 2 DSR Output 3 RxD Output 4 SG Sig Gnd 5 Console Input 6 TxD Input 7...

Page 45: ...or per pinout shown in Figure 3 5 NOTE When AUX 2 Console Mode is enabled the internal Modem is disabled Figure 3 5 AUX 2 Port Console Cabling Modem Line Connection Use cable assembly 135 007 7200 or...

Page 46: ...ies 6 lbs Operating Range Temperature 0 to 50 degrees C operating Relative Humidity 5 to 95 non condensing Altitude 10 000 ft max operating 50 000 ft max non operating Shock and Vibration As normally...

Page 47: ...ng Relative Humidity 5 to 95 non condensing Altitude 10 000 ft max operating 50 000 ft max non operating Shock and Vibration As normally encountered during shipping and handling Power Requirements AC...

Page 48: ...M Pin DB 44M Pin Signal Shield Shield Shield 27 33 RD B 17 32 TD B 28 18 RD A 18 17 TD A 33 8 DCD s 19 44 TCE B 34 6 DSR s 20 29 TCE A 35 5 CTS s 23 40 TC B 42 4 RTS s 24 25 TC A 43 9 DTR s 25 42 RC B...

Page 49: ...3 Installation 3 18 NetPath 100 User s Manual Installation Guide 980 001 0210K November 2000...

Page 50: ...n or via direct connected VT 100 terminal These param eters can also be reconfigured via in band Telnet Management session after the initial installation Additional parameters are configured via in ba...

Page 51: ...mpletion of the self test d The T1 ALARM and FR MGMT LEDs should not be flashing together e All other LED indications should be ignored until configuration has been completed If the LED indications ar...

Page 52: ...ch position 5 selects the coding method B8ZS or AMI Switch position 6 selects whether the Tx data input is aligned with the DCE supplied clock or the DTE supplied clock Switch position 7 selects Frame...

Page 53: ...ots WAN DLCI Address To use the in band WAN Frame Relay Management Channel the WAN Management DLCI Frame Relay Management Channel s PVC Address must be set The DIP switch settings are read and stored...

Page 54: ...red value using the switch positions shown in Table 4 2 to represent each of the decimal digits CAUTION An unintentional parameter change and possible unit reset could occur if the NVM RESET CONFIG pu...

Page 55: ...testing and Test level displays all screens allows performance of tests but no config uration changes The next prompt asks for your name and phone number Enter name and phone number followed by ENTER...

Page 56: ...ys shown at the top center of each screen Body The central portion shows the specific screen details for that screen Command Line User commands are always entered at the bottom of the screen marked by...

Page 57: ...4 Operation 4 8 NetPath 100 User s Manual Installation Guide 980 001 0210K November 2000 This page intentionally left blank...

Page 58: ...MANAGER CONFIGURATION Set Parameters Help Save SNMP COMMUNITY ACCESS CONFIGURATION Set Parameters Help Save CSU STATISTICS HISTORY Help Select Page FRAME MANAGER CONFIGURATION Set Parameters Help Sav...

Page 59: ...e end of this field indicates the option type installed if any S N Serial Number of Unit System Test Fault Highest priority Test or Fault causing disruption of the data path States are Improper Aux2 C...

Page 60: ...X21 NS or blank if none Commands DevConfig DC Advances to Device Configuration Screen CsuConfig CC Advances to CSU DTE Configuration Screen FrameConfig FC Advances to Frame Manager Configuration Scre...

Page 61: ...ress will be learned automatically The first valid IP Address will be learned Once a value is entered or learned automatically it will replace the 0 0 0 0 value and auto learning will be discontinued...

Page 62: ...talled modem 2 Dial String Enter modem AT string with phone number to dial Trap Manager and any other AT codes if required for modem initialization Default is blank NOTE Each character sequence M with...

Page 63: ...omatic dial tone testing of the dial line during power up reset as well as the 4 hour routine test Default No Test Inactivity Logout Set the console session inactivity idle time which when reached wil...

Page 64: ...and CHAP fields will only be displayed if logged in as Supervisor Passwords 1 View Pswrd View Only access password Factory Default 11111111 2 Test Pswrd Test and View access password Factory Default...

Page 65: ...ne connection 6 Ones Dens Selects the Ones Density format to be used 7 T1 Framing Selects T1 Framing format to be used NOTE ANSI or AT T are ESF format SF includes D4 8 DTE TxD Clk Configure the DTE t...

Page 66: ...SA Saves parameters and returns to System View screen Cancel X Returns to System View screen without saving changes Save the CSU DTE Configuration changes when they are all set correctly by entering S...

Page 67: ...the DLCI value NOTE The P C Mgmt DLCI value must NOT be the same as WAN Mgmt DLCI CAUTION If either WAN or P C Mgmt DLCI value is changed the NetPath 100 will perform a system reset after the Save SA...

Page 68: ...an LMI Status Enquiry from the User equipment The ratio of N392 to N393 defines the rate of Bad No LMI inquiries to Count of events beyond which the User link is declared Out of Service This ratio is...

Page 69: ...Help for SNMP Community Access Configuration screen Save SA Saves parameters and returns to System View screen Cancel X Returns to System View screen without saving changes Save the SNMP Community Co...

Page 70: ...4 Operation 980 001 0210K NetPath 100 User s Manual Installation Guide 4 21 November 2000 This page intentionally left blank...

Page 71: ...ss defined Trap Manager will probably not receive this Trap due to this message passing through other CPE equipment affected by the loss of power IP Add Sets the IP Address for each Trap Manager desig...

Page 72: ...3 Clear Holdoff Sets the number of minutes that a trap condition must remain clear before it is declared clear 4 Terminate Delay Sets the time a Dial Out connection will remain in place after the las...

Page 73: ...et 2 Min Pkts for Delay Alarm Setting for the number of packets that must be received within the current interval on a PVC before the PVC Delay Thres average is considered a valid check for that PVC I...

Page 74: ...a subsequent interval fail to equal or exceed the threshold value Applies to auto and manually learned DLCIs 5 PVC Delay Thres NetPath 100 maintains an average delay measurement for each PVC for the c...

Page 75: ...s packets None Neither packet types will be sent 11 Add PVC Inserts one or more additional DLCIs onto the list to be monitored 12 Delete PVC Removes one or more DLCIs from the list PVC TxCR RxCR Mon H...

Page 76: ...4 Operation 980 001 0210K NetPath 100 User s Manual Installation Guide 4 27 November 2000 This page intentionally left blank...

Page 77: ...g or a space to deselect all factory default Parenthesis indicate the subset under which a protocol is grouped such as SNAP Refer to Encapsulation on page 4 14 in this manual for details NOTE Addition...

Page 78: ...e PVC on which the traffic occurred 4 Rank Top Stats By Selection determines whether the Top IP Traffic collection will be ranked by IP traffic with the highest Packet counts or IP traffic with the hi...

Page 79: ...rk communications are restored after the test 3 Coordinate the initiation of this test with the NCC Operator and when told to do so disconnect the T1 Line from the NetPath 100 The NetPath 100 will dia...

Page 80: ...rding optional features such as the ISDN Adapter NetPath 100 diagnostic features include Front Panel LED Indicators BER Testing Statistic gathering and reporting and Alarm reporting LED Indicators Fro...

Page 81: ...receiving properly framed T1 data or is detecting red blue or yellow alarm conditions FLASHING simultaneously with FR MGMT LED indicates software download in process HS PORT TxD Green LED ON indicates...

Page 82: ...de or operator command b Payload loop in response to telco initiated loop code or operator command c Line and Payload Loop codes directed toward the T1 d V 54 loop in response to telco initiated code...

Page 83: ...ated Loopbacks BERT and Test Packet tests Line Lp to Netw Sets a Line Loopback at the T1 interface toward the Network Payld Lp to Netw Sets a Payload Loopback in the CSU toward the Network Send LoopUp...

Page 84: ...tests will prompt for the input of a PVC DLCI destination 2 This test s delay values may not correlate to values displayed on the PVC Statistics Screens because the Link Test Packet size 40 1590 octe...

Page 85: ...E secs Used with optional external Power Control Unit PCU to in terrupt AC Power to the DTE device force reboot of device When issued with a secs parameter power will remain off for the specified leng...

Page 86: ...tics Summary screen is shown in Figure 5 5 Figure 5 5 CSU Statistics Summary Screen System Test Fault Displays blank or the highest priority Test or Fault causing dis ruption of the data path Refer to...

Page 87: ...seconds with one or more Frame errors OR one or more Bi polar Violations ESF Framing Count of seconds with one or more Frame errors OR one or more CRC6 errors SES Severely Errored Seconds Count of se...

Page 88: ...stics for the most recently completed interval of the previous 24 hours The interval can be displayed as time of day rather than a simple count of intervals by including the current_time parameter wit...

Page 89: ...n of all fault displays High Speed Interface Status DTR State of DTR lead when Power is being detected from the DTE States are ON OFF or blank if Power OFF RTS State of RTS lead when Power is being de...

Page 90: ...data frame NOTE When the LMI Protocol is set to None the values for LTO and LFE will be blank Current Displays the total count for each of the performance parameters within the current 15 minute inter...

Page 91: ...Network and User statistics are as described for the previous screen Frame Manager Statistics Summary Interval 1 shows the statistics for the most recently completed interval of the previous 24 hours...

Page 92: ...ration Screen Current in terval statistics are total counts for each parameter within the current interval NOTES Rx Indicates traffic received from the Frame Relay Network Tx Indicates traffic sent to...

Page 93: ...e values are set to 0 zero for PVCs not designated for the sending of Delay monitor packets These values will freeze not update and Delay and Loss measurement packets for ALL PVCs are halted while a T...

Page 94: ...displays Choices are Specific PVC Enter DLCI number or Etc for that PVC Sum of all PVCs Enter Sum or only S Frame Relay traffic parameters displayed are the same as for Current Interval above 10 Secon...

Page 95: ...F243802 Mode M P O TC RC TL RL FD orND Oct P Pkt O Oct TC TxCir RC RxCir TL TxLoss RL RxLoss FD FullDlay orND NetwDlay First DLCI P 16 Current Interval Count 455 of 900 secs DLCI RxPkts TxPkts RxOcts...

Page 96: ...value being used for percent of usage calculations binning for each PVC listed PVC Statistics Summary Name F243802 Mode M P O TC RC TL RL FD orND TxCir P Pkt O Oct TC TxCir RC RxCir TL TxLoss RL RxLos...

Page 97: ...Values are from the second NNI encountered after the Origin Dlvd Percentage of sent packets delivered to the far end NonDEPkts plus DEPkts LstP Counts as above for the Last Loss measurement packet rec...

Page 98: ...ile a Test Pkts to Netw operator initiated test is performed on any PVC Additional commands on these screen are ResetStats RS Clears all counters including 24 hour history ViewHistory VH current_time...

Page 99: ...ber DLCI to be displayed on the screen First Interval F Selects the first interval number of the possible 96 to begin the display of data The data lines 16 lines per screen will be filled by as many s...

Page 100: ...roviding an in dividual line of statistics for each DLCI found within that interval Within the interval the DLCIs are listed in numerical DLCI order with the interval number count placed only on the f...

Page 101: ...ute Interval History Count Displays the number of user defined 1 15 Minute intervals that have been accumulated since the last reset of the counters Protocols Lists up to eight counting categories for...

Page 102: ...is screen are ResetStats RS Clears all Protocol Monitoring and PVC Monitoring statistics counters including history ViewHistory VH current_time optional Advances to Page 1 of the Protocol Monitor Stat...

Page 103: ...at PVC Sum of all PVCs Enter Sum or only S First Interval Selects the interval of the indicated number max of 96 to begin the display of data Performance data is displayed as described on the Protocol...

Page 104: ...5 Diagnostics 980 001 0210K NetPath 100 User s Manual Installation Guide 5 25 November 2000 This page intentionally left blank...

Page 105: ...are Tx Conversation Rx Conversation Tx Talker and Rx Listener Note The parameters displayed depend on whether the Rank Top By setting set on the Protocol Monitor Configuration Screen is Octet or Pack...

Page 106: ...the Network Router The heading shows Destination in Tx mode or Source in Rx mode NOTE The Far fields are not displayed in Talker Listener mode For Rank by Packet the following are displayed Pkts Count...

Page 107: ...Router heading indicates Destination and the Far Network Port Router heading indicates Source Top Talker Conversation Statistics Summary Name F243802 Mode M Tx Rx Rx Rx Conversation Current Interval C...

Page 108: ...as described on the previous pages Note that only the Near User Port Router heading and IP Address es are displayed when ranked by Packet Top Talker Conversation Statistics Summary Name F243802 Mode...

Page 109: ...rval of the indicated number max of 96 to begin the display of data The first six lines display Top Talker Conversation statistics for the first interval the next six lines for the next interval Addit...

Page 110: ...ighest BECN FECN seconds of all PVCs based on the current interval performance In Band PVC Dropped Monitor Packets Highest Dropped packet count of all PVCs based on the current interval performance In...

Page 111: ...rt CSU c No LMI at Frame Switch and NetPath 100 FSU self check FSU sends Trap via modem Call in to Modem Frame Switch CSU Payload loop tests Local Power d No LMI at Frame Switch CSU senses AC Power lo...

Page 112: ...OFF every 5 Secs Improper AUX 2 cable detected Disconnect AUX 2 cable and contact Technical Support immediately ON OFF NetPath 100 fails 45 sec self test Internal circuit fault Replace with known goo...

Page 113: ...ess is by command or as the result of a detected error The NetPath 100 indicates the initiation of the download process by simultaneously flashing the T1 FAULT and FR MGMT front panel LEDs The rate of...

Page 114: ...g the phone number to be called is stored in the NetPath 100 AT Dialing the Router issues the phone number Note It is important that the Router does not have DTR ON unless it wants to use the modem be...

Page 115: ...apply Set to the SNMP objects that are settable Complete the following steps 1 Before you begin be sure that an SNMP community is configured for Read Write access within the NetPath 100 2 Define a com...

Page 116: ...ct to determine the reason access was denied 11 You can now access any SNMP object in the NetPath 100 MIB and perform a SET on the object including objects in the Config ResetStats and TimeEventCmd gr...

Page 117: ...5 Diagnostics 5 38 NetPath 100 User s Manual Installation Guide 980 001 0210K November 2000...

Page 118: ...e 6 1 November 2000 6 Options This section contains installation operation and diagnostic information specific to fac tory Options which are available with NetPath 100 units The Options currently avai...

Page 119: ...6 Options 6 2 NetPath 100 User s Manual Installation Guide 980 001 0210K November 2000 This page intentionally left blank...

Page 120: ...put Connections NetPath 100 rear panel ISDN connectors are shown in Figure 6 2 Figure 6 2 NetPath 100 Rear Panel with ISDN Adapter Frame Relay CSU P O W E R R E A D Y T 1 A L A R M H S P O R T T x D H...

Page 121: ...ta Port pinout and cable details Use cable assembly 135 981 0006 or per pinout shown in Table 6 2 Table 6 1 NetPath 100 ISDN Input Output Connectors and Specifications Connectors Description ISDN Data...

Page 122: ...oximately 45 seconds c The READY and ISDN READY LED will be ON steady after suc cessful completion of the self test d The T1 ALARM and FR MGMT LEDs should not be flashing together e All other LED indi...

Page 123: ...t level displays all screens allows performance of tests but no config uration changes The next prompt asks for your name and phone number Enter name and phone number followed by ENTER If this informa...

Page 124: ...Save SNMP COMMUNITY ACCESS CONFIGURATION Set Parameters Help Save CSU STATISTICS HISTORY Help Select Page FRAME MANAGER CONFIGURATION Set Parameters Help Save CSU DTE CONFIGURATION Set Parameters Hel...

Page 125: ...currently operating the unit The first two digit number indicates the unit s feature set the second indicates the base software revision and the last indicates minor revision level An Alpha character...

Page 126: ...t configured for On Demand operation these fields will not be displayed If configured for On Demand the fields are as follows DTR State of DTR lead ON or OFF RTS State of RTS lead ON or OFF Interface...

Page 127: ...Rate Select the data rate to be used when establishing Backup ISDN connections IMUX Select the method of inverse multiplexing to be used for Backup calls Bond M1 Selects Bonding Mode 1 Protocol to bo...

Page 128: ...rofile Identifier and Directory Number for each of the B Channels of each ISDN Line as assigned by Telco when the ISDN service was established The formats for these fields are as follows SPID Telco ID...

Page 129: ...s initiated Valid range is from 0 to 240 min utes NOTE If the original initiating condition clears for a duration of at least one minute and the Bkp Activate Delay has not yet expired the backup will...

Page 130: ...I Holdoff When the value is not zero this sets the time delay between Network LMI returning to a good state after having failed and the unit notifying the DTE by restoring LMI to the dedicated User Po...

Page 131: ...ew screen Cancel X Returns to System View screen without saving changes CAUTION If any parameter on this screen was changed the ISDN Adapter will perform a reset after the Save SA command is issued Th...

Page 132: ...ically to the CSU line described above The IP Address will be automatically learned when the NVM value is 000 000 000 000 Once learned or set it will not be changed The second option is to learn the a...

Page 133: ...E M I N U S E I S D N R E A D Y L I N E 1 S T A T U S L I N E 2 S T A T U S L I N E 3 S T A T U S L I N E 4 S T A T U S A P COM Company Table 6 3 ISDN Adapter Indicators Nomenclature Description Func...

Page 134: ...e Directory assigned as entered and displayed on the ISDN Configuration screen may not match the actual number to be di aled in order to establish a Dial In connection to the B Channels Contact the Ne...

Page 135: ...st or Fault causing a disruption of the data path or other operation of the unit Refer to the Appendix in this manual for a list and description of all fault displays ISDN Status Test Name F 43802 CSU...

Page 136: ...ON OFF or blank if Power OFF RTS State of RTS lead when Power is being detected from the DTE States are ON OFF or blank if Power OFF Power ON or OFF based on sensing voltage on Tx data lead s from th...

Page 137: ...ty for the interface DTR State of DTR lead ON or OFF RTS State of RTS lead ON or OFF ISDN Demand Displays current status as reported by ISDN Adapter module Status states are ISDN Adp Fault The ISDN ha...

Page 138: ...mmmm indicates the last connection status see Table 6 5 for codes applies to ML PPP inverse multiplexing ONLY Failed xxx mmmm Retry attempts exhausted xxx indicates the latest Cause Code See Note belo...

Page 139: ...sts but this call identity does not 26 Non selected user clearing 84 Call identity in use 27 Destination out of order 85 No call suspended 28 Invalid number format incomplete number 86 Call having the...

Page 140: ...ation Guide 6 23 November 2000 Table 6 5 ML PPP Connection Codes Code Status LCP Link Configuration Protocol negotiation failure Auth Authentication PAP or CHAP failure NCP Network Configuration Proto...

Page 141: ...ntication MLPPP only NCP Network Configuration Protocol negotiation MLPPP only Elapsed Times for Most Recent Out Bound Connection Timer for each B Channel showing the elapsed time of a current call or...

Page 142: ...ufacturers of routers and net work switching equipment The Trace feature is accessed via VT 100 dial in to the NetPath 100 ISDN Adapter module A dial in call is routed to the ISDN Adapter by the unit...

Page 143: ...Activate trace by entering TRACE PPPTRACE followed by ENTER Start Diagnostic Mode by entering DIAG followed by ENTER atdt dial number w 4 CONNECT 9600 ARQ FrameSaver NP 100 FSU ISDN Version 01 29 May...

Page 144: ...agicNumber 158ada97 Netw 0 LCP MRRU 1524 Netw 0 LCP EndpointDisc Type 1 Router6 User LCP Sent CONFIG REQ User LCP MRU 1524 User LCP AuthProto PAP User LCP MagicNumber 9fbfa Netw 0 LCP Received CONFIG...

Page 145: ...ption Trap Reported In Band Modem ISDN ISDN Adapter Fault Adapter failed self test after reset or periodic check In Band ISDN Line Failure Loss of connectivity with CO Switch In Band ISDN Backup Issue...

Page 146: ...ISDN READY LED On steady Continuous cycles of flashing indicate critical internal circuit fault Replace with known good NetPath 100 OFF ISDN Adapter fails Self test Internal circuit fault Replace wit...

Page 147: ...concerning these features ISDN Adapter Software Download Initiation of the download process is by command or as the result of a detected error The ISDN Adapter provides no LED indication for the downl...

Page 148: ...st cur rently active is displayed if any This section provides a list of entries for the Status Fault or Test which may appear for each Title The entries are listed in the tables in the order of highe...

Page 149: ...arm notification that an upstream signal failure has been detected on this T1 facility CSU Threshold Alarm Link Error Threshold reached or exceeded Table A 2 Frame Manager Fault Display Description Cl...

Page 150: ...onnections than configured for Secondary Dwn Spd Backup connection in place using Secondary Dials but with fewer ISDN connections than configured for Connecting Connection is being established Failed...

Page 151: ...mary Dials but with fewer ISDN connections than configured for Online Call Lp On Demand connection in place using Secondary Dials but with fewer ISDN connections than configured for Primary On Line Co...

Page 152: ...correct SPID has been entered for this B Channel B1 SPID Failure A B2 Channel cannot operate due to a SPID failure on its associated B1 Channel LoopUp LoopUp connection in place Connecting Connection...

Page 153: ...ts but this call identity does not 26 Non selected user clearing 84 Call identity in use 27 Destination out of order 85 No call suspended 28 Invalid number format incomplete number 86 Call having the...

Page 154: ...ation Guide A 7 November 2000 Table A 7 ML PPP Connection Codes Code Status LCP Line Configuration Protocol negotiation failure Auth Authentication PAP or CHAP failure NCP Network Configuration Protoc...

Page 155: ...he Device Status Test screen Table A 8 Modem Status Fault Display Description Modem Failure Failure of Modem hardware detected by the unit Dial Line Failure Failure of routine Dial Line test detected...

Page 156: ...ce at Network Port toward Network Circuit Payld Lp to Netw Full T1 Payload loopback in place toward Network Circuit V 54 Lp to Netw Loopback is in place at the User Port toward the Network Circuit in...

Page 157: ...PVC Dlvd Pkt Threshold value DS0s must be assigned to the User Port PVC Delay Alarm PVC Delay Threshold reached or exceeded DS0s must be assigned to the User Port BECN FECN Alarm BECN FECN Error Thre...

Page 158: ...ard Network Circuit Mgmt Line Netw Operator initiated Full T1 Line loopback in place at Network Port toward Network Circuit Mgmt Pyld Netw Operator initiated Full T1 Payload loopback in place toward N...

Page 159: ...work Port toward Network Circuit Payld Lp to Netw Full T1 Payload loopback in place toward Network Circuit V 54 Lp to Netw Loopback is in place at the User Port toward the Network Circuit in response...

Reviews: