3 Installation
3-6
NetPath 100 User’s Manual - Installation Guide
980-001-0210K
November
2000
Connections to
Optional NP 467
Power Control Unit
If this installation includes an NP 467 Power Control Unit (PCU), connections to it are
made as follows.
A. Connect one end of the Switched AC Out cable to its PCU connector, shown in
Figure 3-4 below. Connect the other end of this cable to the AC Input cable of the
device to be controlled (usually the DTE device connected to the User Port of the
NetPath 100).
CAUTION
Do not plug the power cord from the NetPath 100 into the
SWITCHED AC OUT cable of the Power Control Unit. This
is an invalid configuration.
B. Connect one end of the Control/Power cable to the PCU connector marked “See
Users Manual”, shown in Figure 3-4. Connect the other end to the Control Output
connector on the rear panel of the NetPath 100, shown in Figure 3-3.
C. Verify that the proper voltage is present at the outlet to be used (125 VAC, 50-60
Hz). If the outlet voltage is correct, connect one end of the AC IN cable to its PCU
connector. Plug the other end of this cable into the AC outlet.
Figure 3-4 Power Control Unit Connections
Continue the installation by making Input/Output connections and Configuring the
NetPath 100 as described in the following sections of this manual.
AC IN C able
C onnect to:
AC O utlet
(source)
Sw itched AC O ut C able
C onnect to:
D TE device AC Input
for
Fram eSaver C ontrolled Pow er
C ontrol / Pow er C able
C onnect to:
N P 64 Pow er C onnector
or
N P 100, 120
C ontrol O utput C onnecto r
S EE
U S ER S
M AN U AL
S W IT C H ED
AC O U T
125V AC
5A M AX
AC IN
125V AC
5.5 AM P S M AX
50-60H z
W A R N IN G !
N O U S ER S ER V IC E AB L E P AR T S IN S ID E
H IG H IN T ER N AL V O L TAG ES PR E SE N T
IN T ER N AL S H O C K H AZAR D PR E SE N T
F ra m e S a v e r
13
3RZHU &RQWURO 8QLW
T M