4 Operation
4-26
NetPath 100 User’s Manual - Installation Guide
980-001-0210K
November
2000
10. Auto & Manual - Specifies the Tx and Rx CIR value and Mon (monitoring
packet(s)) type to be used when PVCs are added to the statistics list. Valid CIR
values are 0 through 1536, default value is zero.
Auto - When a non-configured PVC is detected, the indicated settings are used un-
til reconfigured by an operator, learned from the LMI, or the PVC is un-
learned (via reset or software purge).
Manual - For PVCs manually added (using the AddPVC command), the param-
eters will be as specified here.
Mon - Selects the Monitor setting for PVCs added automatically and manually.
Defaults are None for Auto, and Delay for Manual.
Dlay = Delay packets only.
Loss = Loss packets only.
Both = Delay and Loss packets.
None = Neither packet types will be sent.
11. Add PVC - Inserts one or more additional DLCIs onto the list to be monitored.
12. Delete PVC - Removes one or more DLCIs from the list.
PVC,TxCR,RxCR,Mon - Heading under which the DLCIs and parameters are listed
(in numerical order) for all PVCs to be included for continuous background per-
formance measurement. Up to a maximum of 270 DLCIs may be listed.
NOTE: Additional pages displaying the DLCIs are accessed using the [P=]
command as shown on the top of the screen.
Commands:
Help [?] - Advances to “Help” for PVC Performance Configuration screen.
Save [SA] - Saves parameters and returns to System View screen.
Cancel [X] - Returns to System View screen without saving changes.
Save the PVC Performance Configuration changes when they are all set correctly by
entering “SA” followed by ENTER. This will also return the user to the System View
screen.
Proceed to Protocol Monitor Configuration, selecting [MC] by typing “MC” followed
by ENTER.