4 Operation
980-001-0210K
NetPath 100 User’s Manual - Installation Guide
4-3
November 2000
CSU
Parameters
To set the T1 Line configuration and CSU operating mode:
1. Set the two-position DIP Switch - 1 = ON, 2 = OFF.
2. Set the 12-position DIP Switch to select the configuration.
3. Depress the NVM RESET / CONFIG push button for at least one second to enter
the parameters in the unit’s NVM.
The meaning of the 12-position DIP Switch settings are shown in Figure 4-2 and de-
scribed as follows:
Switch positions 1 - 2 select the LBO setting from 0 to -22.5 dB.
Switch positions 3 - 4 select the Framing Mode of ANSI, AT&T, or SF.
Switch position 5 selects the coding method B8ZS or AMI.
Switch position 6 selects whether the Tx data input is aligned with the DCE-supplied
clock, or the DTE-supplied clock.
Switch position 7 selects Frame Relay or Transparent (Clear Channel) mode.
Switch positions 8 - 12 are reserved for future use and should remain off.
Figure 4-2 Set CSU Parameters
Table 4-1 Two-Position DIP Switch Functions
Pos. 1
Pos. 2
Function
OFF
OFF
Set WAN Management DLCI address
OFF
ON
Set time slots
ON
OFF
Set CSU parameters
ON
ON
Reserved
S et C S U Param eters
* C hanges to these item s w ill cause unit to reset.
R eserved (O ff)
LB O :
00 = 0
01 = -7.5
10 = -15.0
11 = -22.5
Fram e:
00 = AN SI
01 = AT& T
10 = SF
11 = R esv.
O n = AM I, O ff = B 8Zs
O n = D TE, O ff = D C E
(Transm it D ata C lock S ource)
O n = Transparent (C lrC han) *
O ff = Fram e R elay M anagem ent *