Appendix
980-001-0210K
NetPath 100 User’s Manual - Installation Guide
A-9
November 2000
System
Test/Fault
System Test / Fault shows the highest priority System related test or fault currently de-
tected. This is displayed on the System View, CSU Statistics Summary and Frame
Manager Statistics Summary screens.
Table A-10 System Test/Fault
Display
Description
Improper Aux2 Cable
Improper cable connection has been detected (Pin 8 may not be used.)
NVM Failure
Failure of NVM (Non-Volatile Memory) detected by the unit and the latest
configuration may not have been saved.
Lp to User
Loopback is in place at the User Port toward the User Circuit.
2047 Payld to User
2047 pattern BERT is being sent toward the User Circuit.
LMI Netw Failure
Invalid or no response to LMI Status enquiries toward Network. DS0s must be
assigned to the User Port.
LMI User Failure
Invalid or no LMI Status requests from User equipment. DS0s must be assigned to
the User Port.
CSU Fault
Failure of CSU related hardware detected by the unit.
Line Lp to Netw
Full T1 Line loopback in place at Network Port toward Network Circuit.
Payld Lp to Netw
Full T1 Payload loopback in place toward Network Circuit.
V.54 Lp to Netw
Loopback is in place at the User Port toward the Network Circuit, in response to a
V.54 LoopUp code from the Network (only if DS0s are assigned to the User Port.)
QRSS to Netw
QRSS pattern BERT is being sent toward the Network Circuit.
Alt Ones to Netw
Alternating Ones pattern BERT is being sent toward the Network Circuit.
2047 Payld to Netw
2047 pattern BERT is being sent toward the Network Circuit.
CFA/Red Alarm
Detected loss of T1 facility.
Rmt/Yellow Alarm
Carrier alarm notification that Transmit failure from this DCE has been detected on
this T1 facility.
AIS/Blue Alarm
Carrier alarm notification that an upstream signal failure has been detected on this T1
facility.
Netw Threshold Alarm
Network Link Error Threshold (Data Frame Error Seconds) reached or exceeded.
DS0s must be assigned to the User Port.
User Threshold Alarm
User Link Error Threshold (Data Frame Error Seconds) reached or exceeded. DS0s
must be assigned to the User Port.
CSU Threshold Alarm
Link Error Threshold reached or exceeded.
PVC Drpd Mon Alarm
PVC Dropped Monitor Packet Threshold reached or exceeded. DS0s must be
assigned to the User Port.