4 Operation
4-2
NetPath 100 User’s Manual - Installation Guide
980-001-0210K
November
2000
Power On
With all the connections completed, the NetPath 100 is ready to be powered on.
Proceed by holding in the recessed push button switch labeled “NVM RESET /
CONFIG” on the unit’s rear panel while plugging in the power cord and continue to
hold the button for approximately four (4) seconds. This will “clear” the unit’s NVM,
resetting all the configuration parameters to their default values. After the NVM Reset
button is released, the NetPath 100 will go through the power-on sequence as follows:
a. The POWER LED will light immediately and stay on.
b. The READY LED will flash while the unit performs it’s self-test (test
duration - approximately 45 seconds).
c. The READY LED will be ON steady after successful completion of
the self-test.
d. The T1 ALARM and FR MGMT. LEDs should not be flashing
together.
e. All other LED indications should be ignored until configuration has
been completed.
If the LED indications are not as described above, refer to section 5 Diagnostics of this
manual. If operation looks normal, proceed with DIP Switch Configurations.
NOTE: If the Dial Line has not been connected to the NetPath 100 prior to powering
the unit on, the unit will issue a Dial Line Failure In-Band Trap to the Trap Manager
after it completes its Modem and Dial Line self test.
DIP Switch
Configurations
The “Configuration” DIP Switches are located on the rear panel of the NetPath 100,
and appear as shown in Figure 4-1.
Figure 4-1 Configuration DIP Switches
The 12-position DIP Switch on the left selects the specific parameters, while the two-
position DIP Switch on the right selects the function.
The functions and their switch positions are shown in Table 4-1.
C O N F IG U R ATIO N
O
N
1 2 3 4 5 6 7 8 9 1 0 1 1 1 2
O
N
1 2