5 Diagnostics
5-6
NetPath 100 User’s Manual - Installation Guide
980-001-0210K
November
2000
Commands:
ResetTest [RT] - Resets BERT or PVC result counters without disrupting the test
operation and refreshes all dynamic information contained on the screen.
InjectErr [IE secs] - Injects a single bit error into the BERT stream. When issued
without the “secs,” a single bit error will be injected at execution of this command.
When issued with a “secs” value between 1 - 255, a single bit error will be injected
once a second for the number of “secs” entered (user can issue other commands while
this takes place in background).
RebootExt [RE secs] - Used with optional external Power Control Unit (PCU) to in-
terrupt AC Power to the DTE device (force reboot of device). When issued with a
“secs” parameter, power will remain off for the specified length of time (1 - 300 sec-
onds). When issued as “RE” only, PCU output power will be interrupted for five sec-
onds at the execution of this command.
Help [?] - Advances to “Help” for PVC Performance Configuration screen.
Close [X] - Returns to System View screen.
AutoUpdate [AU] - Provides automatic screen update and refresh (every five sec-
onds) of all status and Test (when active) results. No changes can be made while in this
mode, and the bottom lines on the screen are replaced as shown in Figure 5-4. AutoUp-
date is exited by pressing ENTER.
Figure 5-4 Auto Update Screen Change
---> Screen updates every 5 seconds <---
---> Press Enter for Command Prompt <---