46
2-2-3 DIP switch
Set the operational options of the laser marker with the
DIP switch equipped on the controller rear side.
ワㄐㄕㄊㄆ
• A plastic cover is installed on the DIP switch. Install
this cover always to avoid the dust penetration to the
controller.
ンㄆㄇㄆㄓㄆㄏㄆ
• The initial setting of all DIP switches is OFF.
• Turn OFF the power at DIP switch setting.
Item
Description
No. 1
System reservation. Keep OFF state.
No. 2
Select the control method, I/O or command for some specific operations.
ON
Control by serial communication commands for the following operations
• Laser pumping (LSR)
• Shutter control (SHT)
• Guide laser (GID)
• Laser check radiation (SPT)
• Laser power measurement (PWM)
• Test marking (TST)
OFF
Control by I/O for the following operations
• Laser pumping
• Shutter control
• Guide laser radiation
No. 3
Select the ON/OFF of the buzzer sound to notify the alarm or warning occurrence.
ON
Disables the buzzer sound for alarm or warning state.
OFF
Enables the buzzer sound for alarm or warning state.
No. 4
Select the ON/OFF of the password lock to allow the settings of the screen. Refer to
“Operation manual” for the password settings.
ON
Disables the password lock.
OFF
Enables the password lock.
ON
OFF
Rear of controller
LP-M200/M205/M500/M505
LP-MA00/MA05/MA06
DIP switch
ME-LPM-SSM-10
Summary of Contents for LP-M Series
Page 16: ...16 MEMO ME LPM SSM 10...
Page 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Page 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Page 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Page 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Page 148: ...Troubleshooting ME LPM SSM 10...
Page 169: ...Index ME LPM SSM 10...
Page 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Page 173: ...No 9000 0066 34V...