2-2-2 Controller
Front
5
9
4
3
2
10
8
1
6
7
10
2
8
1
6
7
5
9
4
3
LP-M200/M205/M500/M505
LP-MA00/MA05/MA06
1. Key switch: POWER
This key switch is used to start the laser marker system.
Turn ON (|) the switch to start-up the system, and turn OFF (O) the switch to shutdown
the system.
Only when the key switch is turned OFF (in O position), the key can be pulled out.
When the laser marker is not in use, the key should be in safekeeping by a laser safety
manager.
In case of turning ON the power supply after turning OFF, leave the interval five seconds or more between ON and
OFF.
Do not turn off the power supply while the system starts (during MAIN indicator is flashing).
2. Controller display panel
The indicator that shows the status of laser radiation and the laser
marker.
No.
Display name
Status
Indication
q
FILE No. / ERROR CODE
Normal state
Displays selected file No.
Alarm or warning status
Displays error code No. Refer to
w
MAIN
System is powered on
Green lighted-up
System under starting up
(uncompleted)
Green flashing
e
MARKING
Being in laser emitting
Orange lighted-up
ヱヰヸユ
ン
ON
OFF
w
e
q
ME-LPM-SSM-10
Summary of Contents for LP-M Series
Page 16: ...16 MEMO ME LPM SSM 10...
Page 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Page 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Page 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Page 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Page 148: ...Troubleshooting ME LPM SSM 10...
Page 169: ...Index ME LPM SSM 10...
Page 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Page 173: ...No 9000 0066 34V...