22
1
Internal shutter
This is a shutter inside the head. The emission of laser beam is stopped by closing the
internal shutter.
2
Laser radiation indicator
The operations of the laser radiation indicator are as follows:
Laser marker status
Head indicator
Controller indicator
Non-laser pumping
Lights-out
Lights-out
Laser pumping is in progress (uncompleted) and shutter
closed
White flashing
Lights-out
Laser pumping is in progress (uncompleted) and shutter
opened
Green flashing
Lights-out
Laser pumping is completed and shutter closed
White lighted-up
Lights-out
Laser pumping is completed and shutter opened
Green lighted-up
Lights-out
Being in laser emitting
Orange lighted-up
Orange lighted-up
WARNING
• If the laser radiation indicator is placed out of the sight of operators, place the
external indicator light or warning lamp on the immediately apparent place on
the system.
3
Key switch
The key switch is used for the system power ON/OFF.
To prevent the unauthorized operation, the system key should be in safekeeping by a
laser safety manager.
4
Alarm reset switch
This switch is used to reset the system when an alarm generates. LED lights up in blue
when an alarm generates.
Release the cause of alarm and press this switch.
5
Emergency stop switch
This switch is equipped in the front side of the controller.
Push the switch at emergency to stop the laser radiation immediately.
The laser pumping is stopped forcibly and laser radiation stops.
Turn the switch to the direction of the arrow to release it.
6
Laser stop input
(Input terminal)
The input terminal equips Laser Stop signal.
Opening either of the signals disables the laser emission as follows. Construct the
safety system by connecting it to the door or switch of the equipment.
• Operation when laser stop 1 is released:
When laser is not radiating: The internal shutter is closed.
When laser is radiating: The internal shutter is closed and laser pumping turns off.
• Operation when laser stop 2 is released:
The internal shutter is closed and laser pumping turns off.
Refer to “3-3-3 Signals on input/output terminal” (P.80) for details.
7
Input/output terminal
The terminal equips various signals, such as shutter input, marking output, mark end
output, ready output etc.
Use these signals for the purpose of controlling other external safety devices, such as
an indicating lamp.
8
Interlock connector1
9
Interlock connector2
This connector is used to construct the interlock system to stop laser pumping and
radiation. Opening this connector makes laser pumping and radiation to stop forcibly.
Refer to “Construction of interlock system” (P.26) for details.
Using Interlock 1 , 2 and a safety relay unit, the safety designed system with the
double-circuit of the interlock can be constructed.
10 Laser gate
(Only for LP-Mxxx-S
type)
This is the device inside the head which acts as a shield from the laser beam.
The laser beam is shut off by the external control signal.
11 Laser gate terminal
(Only for LP-Mxxx-S
type)
This is a terminal for inputting laser gate opening/closing control signals from external
device. Construct a safety system for the device using safety PLC.
Refer to “3-8 Control of Laser Gate” (P.117) for details.
*1 : Not equipped on LP-Mxxx-LS1 type.
ME-LPM-SSM-10
Summary of Contents for LP-M Series
Page 16: ...16 MEMO ME LPM SSM 10...
Page 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Page 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Page 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Page 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Page 148: ...Troubleshooting ME LPM SSM 10...
Page 169: ...Index ME LPM SSM 10...
Page 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Page 173: ...No 9000 0066 34V...