143
4-2-12 Replacement of fuse
Replace fuse of the controller when blowing.
The power of the laser marker cannot be turned on if the fuse is blown.
Models of replacement parts
Be sure to use the following type of fuse: If the user applies any other fuses than the specified one, failure might result.
Laser marker model
Type
Model
LP-M500, LP-M505,
LP-MA00, LP-MA05, LP-MA06
Time Lag Fuse (Rating 250V 10A)
0215010
(made by Littelfuse)
LP-M200, LP-M205
Time Lag Fuse (Rating 250V 6.3A)
021506.3
(made by Littelfuse)
Steps for replacement
1.
Remove causes for fuse blowing.
2.
Turn OFF the key switch of the controller, and disconnect the AC power cable.
3.
Turn the fuse holder on the back side, and remove
the fuse.
4.
Replace it with new one.
5.
Turn the fuse holder, and install the fuse.
Fuse
holder
ME-LPM-SSM-10
Summary of Contents for LP-M Series
Page 16: ...16 MEMO ME LPM SSM 10...
Page 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Page 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Page 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Page 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Page 148: ...Troubleshooting ME LPM SSM 10...
Page 169: ...Index ME LPM SSM 10...
Page 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Page 173: ...No 9000 0066 34V...