Outside Transfer Sequence—Call Transfer to Outside Answer Mode
Specifies the answering method the system uses to detect whether the destination party has answered the
transferred trunk call.
Value Range
Guidance
: The system plays the following guidance before connecting the line to the destination party: "You
have a call. To answer the call, press [1]. Otherwise, press [2] and hang up." If the destination party presses
"1", he or she will be able to answer the transferred trunk call. The system continues playing this guidance for
the time specified in
Dialling Parameters—Outgoing Call No Answer Time (10-90 s)
. If the transferred party does not answer the call within this time, the system
considers it as a No Answer call.
Analyze
: The system monitors the status of the trunk, recognises that the destination party goes off-hook, and
connects the line.
Feature Guide References
3.2.1.7 Call Transfer to Outside
Trunk Group (1–64)—Trunk Group No.
Specifies a trunk group for making settings for EFA Transfer, Caller ID Callback, and Outside Line Access
Sequence for Caller ID Callback. Selecting different trunk groups from this drop-down list allows settings to be
made for each trunk group.
Value Range
1–64
Trunk Group (1–64)—EFA Transfer
Specifies whether or not the system uses EFA (External Feature Access) when transferring incoming trunk
calls to another trunk. If set to "Enable", the system transfers incoming trunk calls to another trunk according
to "EFA Transfer Sequence" specified in "Transfer to Outside". If set to "Disable", the system transfers incoming
trunks calls to another trunk according to
Outside Transfer Sequence—Call Transfer to Outside
Sequence (Up to 16 digits / [0-9 * # D F R T , ; N])
.
Value Range
Enable, Disable
Trunk Group (1–64)—Caller ID Callback
Specifies whether or not the system allows a subscriber to call back the party who left a message in his or her
mailbox by using the caller ID information sent from the PBX. This setting applies to the trunk number used
when the message with Caller ID information was left in his or her mailbox.
Value Range
Enable, Disable
Trunk Group (1–64)—Outside Line Access Sequence for Caller ID Callback (Up
to 16 digits / [0-9 * # D F R T , ; ])
Specifies the sequence of trunk access numbers for Caller ID Callback. This parameter is available when the
system executes Caller ID Callback without using EFA.
PC Programming Manual
795
24.4 UM Configuration—[5-4] System Parameters—Parameters
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...