Maximum Continuous Tone Time (0-60 s)
Specifies the length of time the system waits when a continuous tone is detected before it disconnects the call.
Value Range
0–60 s
Maximum Cyclic Tone Time (0-60 s)
Specifies the length of time the system waits when a cyclic tone is detected before it disconnects the call.
Value Range
0–60 s
Maximum Call Duration (0-60 min)
Specifies the maximum duration of calls. If the system detects no DTMF signals for the specified amount of
time, it terminates the call. Calls will not be terminated while playing or recording messages. If this setting is
set to "0", calls will not be terminated.
Value Range
0–60 min
Transfer to Outside
These parameters determine how the system will transfer calls to a trunk via the following features: Call
Transfer Service, Custom Service, Personal Custom Service, Caller ID Callback, Call-through Service.
Outside Transfer Sequence—Call Transfer to Outside Sequence (Up to 16
digits / [0-9 * # D F R T , ; N])
Specifies the sequence the system uses to transfer calls to trunks.
Value Range
Max. 16 digits consisting of 0–9, , # and special codes
D
: Disconnecting
F
: Flash (Recall)
R
: Ringback Tone Detection
T
: Dial Tone Detection
,
: Dial Pause for 1 s (default)
;
: Dial Pause for 3 s (default)
N
: Telephone Number Dialling
0–9, , #
: Dial Code
Feature Guide References
3.2.1.7 Call Transfer to Outside
PC Programming Manual
793
24.4 UM Configuration—[5-4] System Parameters—Parameters
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...