VM Trunk Group No.
Specifies the number of the VM trunk group sent to the VPS when the incoming call destination is the floating
extension number of a VM (DPT) Group. The VM trunk group number is used to allow the VPS to send the
applicable greeting message to the caller.
Value Range
1–48
CLI for DIL
When CLI distribution is enabled for a trunk to which DIL distribution is set, incoming trunk calls will be
distributed to the CLI destinations (instead of the DIL destinations) if the caller’s identification number is found
in the System Speed Dialling Table.
CLI distribution can be enabled or disabled for each time mode (day/lunch/break/night) on a trunk basis.
The
Shelf
,
Slot
, and
Port
for each item are displayed for your reference. For details, see
9.1 PBX Configuration—[1-1] Configuration—Slot
.
Card Type
Indicates the trunk card type (reference only).
Value Range
Card type
Feature Guide References
2.1.1.1 Incoming Trunk Call Features—SUMMARY
Trunk Property
Indicates the networking type of each trunk (reference only).
Value Range
Public, Private(TIE), VPN
Feature Guide References
Distribution Method
Selects the distribution method for incoming trunk calls. The value range of this setting depends on the card
type and
Trunk Property
assigned for each trunk.
Value Range
DIL: Distribution depends on the trunk through which the calls arrive
DDI/DID: Distribution depends on the DDI/DID number of the calls
PC Programming Manual
673
18.2 PBX Configuration—[10-2] CO & Incoming Call—DIL Table & Port Settings
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...