1.
Ensure that the Trunk Adaptor is connected to the network and a power supply, and that all ports to be set
are OUS.
2.
Click
Trunk Adaptor
. The
Trunk Adaptor List
screen is displayed.
3.
Enter a name (20 characters or less) for the Trunk Adaptor in
Trunk Adaptor Name
.
4.
Enter the Trunk Adaptor’s IP address in
Trunk Adaptor IP Address
.
5.
To confirm that the setting is correct, click
CONNECT
. If the setting is correct, the Trunk Adaptor’s Web
Maintenance Console will open in a new browser window.
For details about the Trunk Adaptor’s Web Maintenance Console, refer to the documentation of the Trunk
Adaptor.
6.
Click
Next
. The
Set Trunk Adaptor
window will open.
7.
In
Virtual SIP Gateway - Port Property - No. Range
, specify
From
and
To
to select a range of SIP
connections to be used with the Trunk Adaptor. These numbers correspond to the
No.
column of the main
Port Property
screen.
8.
In
Name : IP Address
, select a name and IP address previously entered on the
Trunk Adaptor List
screen.
9.
In
SIP Server Port Number
, enter the SIP server’s port number.
10.
In
SIP Account / User Name
, enter a 3- to 5-digit number in
From
.
11.
Click
Finish
, and the following settings are implemented:
•
tab will be set to match the selected
Trunk Adaptor.
•
The
and
tab will be set to the value specified in
SIP Account / User Name
, increased by 1 for each connection (i.e. if "401" was specified,
User
Name
and
for No. 1 will be set to "401", and then for No. 2 they will be set to
"402", etc.).
12.
In the
tab of the
V-SIPGW—Port Property
screen, set
to
PBX-CLIP
for each port that was set to be used with the Trunk Adaptor.
Main
The
Shelf
,
Slot
, and
Port
for each item are displayed for your reference. For details, see
9.1 PBX Configuration—[1-1] Configuration—Slot
.
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS
or
OUS
for the port.
This option is only available in On-line mode.
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Connection Attribute
Specifies whether to connect a port to a Trunk Adaptor or use it as a SIP gateway.
Value Range
SIP Provider, Trunk Adaptor
PC Programming Manual
223
9.10 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...