Dial—Analogue CO Inter-digit (s)
Specifies the length of time within which subsequent digits of a telephone number must be sent to an analogue
trunk. If no digit is sent before this time expires, the PBX recognises end of dialling and stops muting the
caller’s voice over the analogue trunk.
Value Range
1–15 s
Dial—Analogue CO Call Duration Start (s)
Specifies the length of time between the end of dialling and the start of the SMDR timer for outgoing analogue
trunk calls.
Value Range
0–60 s
Feature Guide References
2.22.1.1 Station Message Detail Recording (SMDR)
Intercept Routing No Answer (IRNA)—Day (s), Lunch (s), Break (s), Night (s)
Specifies the length of time until an unanswered trunk call is redirected to the intercept routing destination in
each time mode.
Note that this setting is only valid for extensions whose
Intercept No Answer Time—Day, Lunch, Break,
Value Range
1–240 s
PC Programming Manual References
12.1.1 PBX Configuration—[4-1-1] Extension—Wired Extension—Extension Settings—Intercept No Answer
Time—
Intercept No Answer Time—Day, Lunch, Break, Night
Feature Guide References
Recall—Hold Recall (s)
Specifies the length of time until the holding extension receives a Hold Recall ring or alarm tone when a held
call remains unretrieved.
Value Range
0 (disable the Hold Recall)–240 s
Feature Guide References
362
PC Programming Manual
10.3 PBX Configuration—[2-3] System—Timers & Counters
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...