Value Range
Max. 16 digits consisting of 0–9, , # and special codes
D
: Disconnecting
F
: Flash (Recall)
R
: Ringback Tone Detection
T
: Dial Tone Detection
,
: Dial Pause for 1 s (default)
;
: Dial Pause for 3 s (default)
0–9, , #
: Dial Code
Number of Digits in Telephone Number (1-20)
Specifies the number of digits for local area telephone numbers. According to this parameter, telephone
numbers dialled by the system can be distinguished as either local calls or long distance calls.
Value Range
1–20
E-mail Option
E-mail Integration allows the system to send new message notification or to send recorded voice messages
as file attachments to subscribers via e-mail. The following settings must be made in order for the system to
use E-mail Integration features.
Mail Address (Up to 128 ASCII characters)
Specifies the mail address of the Unified Messaging system.
Value Range
Max. 128 characters
Feature Guide References
3.2.1.28 Message Waiting Notification—E-mail Device
Full Name (Up to 64 ASCII characters)
Specifies the full name that will appear in e-mail messages sent by the Unified Messaging system.
Value Range
Max. 64 characters
Feature Guide References
3.2.1.28 Message Waiting Notification—E-mail Device
Maximum Message Length (Selection)
Specifies whether voice messages sent as e-mail attachments will have a limit to their length.
796
PC Programming Manual
24.4 UM Configuration—[5-4] System Parameters—Parameters
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...