Incomplete Call Handling for Busy
Specifies how the Unified Messaging system handles a call when the extension is busy. Click
Edit
for the
extension to change, programme the settings, and click
OK
to finish.
Note
•
This setting can be changed by subscribers.
•
More than one option can be selected.
Value Range
Leave a Message
: Allows the caller to record a message.
Transfer to a covering extension
: Transfers the caller to a covering extension.
Page the mailbox owner by intercom paging
: Pages the subscriber by intercom.
Transfer to operator
: Transfers the caller to an operator.
Return to top menu
: Lets the caller return to top menu and try another extension.
Transfer to specified Custom Service Menu
: Transfers the caller to the specified Custom Service.
Feature Guide References
3.2.2.15 Incomplete Call Handling Service
Call Transfer Anytime in Incomplete Handling Menu
Specifies whether callers can input an extension number to transfer their call while the Automated Attendant
service is playing an Incomplete Call Handling menu.
Value Range
Enable, Disable
Notification Parameters
The Unified Messaging system is able to notify a subscriber when a new message is recorded in his or her
mailbox. There are 3 methods the system can use for notification:
–
Lighting the Message Waiting Lamp on the subscriber’s extension telephone.
–
Calling a pre-programmed device (external telephone, etc.). A maximum of 3 devices (Device 1, 2, 3) can
be programmed per mailbox.
–
Sending an e-mail to a designated address.
Message Waiting Lamp
If set to "Enable", the Message Waiting Lamp of the subscriber’s telephone turns on when a new message is
recorded.
Value Range
Disable, Enable
Feature Guide References
3.2.1.29 Message Waiting Notification—Lamp
712
PC Programming Manual
20.1.2 UM Configuration—[1-2] Mailbox Settings—Full Setting
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...