11.5.1.1 PBX Configuration—[3-5-1] Group—Incoming Call
Distribution Group—Group Settings—Member List
Each incoming call distribution group can have a maximum of 128 members (extensions) assigned to it, and
each member can have its own delayed ringing and Wrap-up time settings. An extension can be a member of
multiple incoming call distribution groups. An ICD Group can also contain cellular phones, and network ICD
groups (ICD groups at other PBXs in a network) using virtual PS (see
in the Feature
Guide). The forward destination assigned to a virtual PS (e.g., a cellular phone) can act as a member of an
ICD group. Select the desired ICD group (1–128) from the
ICD Group No.
list.
To assign members to the group, enter directly or click
Extension No. Setting
). To copy the members to another group, click
Member list copy
, select the group, and click
OK
.
Extension Number
Specifies the extension number of each member. In addition to the extension numbers of PT, SLT, and PS
extensions, floating extension numbers of PS Ring groups can also be specified.
Value Range
Max. 5 digits (consisting of 0–9)
PC Programming Manual References
11.8 PBX Configuration—[3-8] Group—PS Ring Group
Feature Guide References
2.2.2.1 Incoming Call Distribution Group Features—SUMMARY
Extension Name
Indicates the name of the extension (reference only).
Value Range
Max. 20 characters
PC Programming Manual References
11.8 PBX Configuration—[3-8] Group—PS Ring Group
Feature Guide References
2.2.2.1 Incoming Call Distribution Group Features—SUMMARY
Delayed Ring
Specifies the delayed ringing setting of each member. (Applicable when the call distribution method of the
incoming call distribution group is set to
Ring
.)
Value Range
Immediate, 1–6 Rings, No Ring
484
PC Programming Manual
11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution Group—Group Settings
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...