The
Shelf
,
Slot
, and
Port
for each item are displayed for your reference. For details, see
9.1 PBX Configuration—[1-1] Configuration—Slot
.
Extension Number
Specifies the extension number of the port.
Value Range
Max. 5 digits (consisting of 0–9)
Extension Name
Specifies the extension name of the port.
Value Range
Max. 20 characters
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS
or
OUS
for the port.
This option is only available in On-line mode.
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Phone Location
Specifies the type of extension connected to the port.
Value Range
Local: The extension is located on the same network as the PBX (standard configuration).
Remote (SBC): The extension is accessing the PBX remotely (Simple Remote Connection).
Remote (MRG): The extension is accessing the PBX remotely (use Media Relay Gateway).
Feature Guide References
5.2.2.1 Simple Remote Connection
Web-MC Ability
Specifies whether the Web programming is allowed on the KX-UT series SIP phone connected to the port by
enabling the Web port setting on the phone’s menu. For details about Web programming for KX-UT series SIP
phones, refer to the documentation of the phone.
Value Range
Enable, Disable
PC Programming Manual
293
9.20 PBX Configuration—[1-1] Configuration—Slot—V-UTEXT—Port Property
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...