Fax No Answer Time (5-60s)
Specifies the length of time (in seconds) that the system waits for the main or alternate fax extension to answer
a fax call before taking other action, such as notifying the Fax Manager that the fax could not be received.
Value Range
5–60 s
Fax Manager Mailbox No.
Specifies the mailbox number of the Fax Manager. The system will notify the Fax Manager of the status of fax
calls depending upon the settings of the
parameters.
Value Range
Fax No Answer Coverage Mode
Determines what action the system takes when an incoming fax call could not be answered by the main or
alternate fax extension. The system can announce to the Fax Manager the number of unanswered fax calls.
The number announced is the number of unanswered fax calls since the last time the system notified the Fax
Manager. This announcement is heard when the Fax Manager logs in to his or her mailbox.
Value Range
No
: The system will not notify the Fax Manager when fax calls were not answered.
Mbx
: The system will announce the number of unanswered fax calls to the Fax Manager when the Fax Manager
logs in to his or her mailbox.
Ext
: The system will announce the number of unanswered fax calls to the Fax Manager by calling the Fax
Manager’s extension.
Fax Notification Mode
Determines what action the system takes when an incoming fax call is successfully received by the main or
alternate fax extension. The system can announce to the Fax Manager the number of received fax calls. The
number announced is the number of received fax calls since the last time the system notified the Fax Manager.
Value Range
No
: The system will not notify the Fax Manager when fax calls are answered.
Mbx
: The system will announce the number of successfully received fax calls to the Fax Manager when the
Fax Manager logs in to his or her mailbox.
Ext
: The system will announce the number of successfully received fax calls to the Fax Manager by calling
the Fax Manager’s extension.
Disconnect Parameters
Maximum Silence Time (0-60 s)
Specifies the length of silence detected by the system before the system disconnects the call.
Value Range
0–60 s
792
PC Programming Manual
24.4 UM Configuration—[5-4] System Parameters—Parameters
Summary of Contents for KX-NS300CN
Page 12: ...12 PC Programming Manual Table of Contents ...
Page 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Page 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Page 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Page 30: ...30 PC Programming Manual 1 2 2 PC Programming Using Off line Mode ...
Page 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Page 56: ...56 PC Programming Manual 3 1 Home Screen ...
Page 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Page 164: ...164 PC Programming Manual 8 4 2 Users ICDG Management ACD Report ...
Page 622: ...622 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Page 646: ...646 PC Programming Manual 15 5 PBX Configuration 7 5 TRS Miscellaneous ...
Page 658: ...658 PC Programming Manual 16 7 PBX Configuration 8 7 ARS Authorisation Code for TRG ...
Page 684: ...684 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Page 702: ...702 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Page 774: ...774 PC Programming Manual 23 4 UM Configuration 4 4 Service Settings Holiday Table ...
Page 798: ...798 PC Programming Manual 24 4 UM Configuration 5 4 System Parameters Parameters ...
Page 829: ...Feature Programming References PC Programming Manual 829 ...