Chapter 4 Explanation of Functions
4-5
4
Cl
as
s
Function
Details
Initial value
Memory
change*1
Ref.
Page
O
U
T
S
et
ti
ng
Analog Output at
Alarm
Sets the analog output status at
alarm operation.
Hold previous
value
Fixed Value
Fixes the analog output status
at alarm operation.
+10.800[V]
Analog Output at
Data Unfixed
Sets the analog output status at
data unfixed.
-10.800[V]
Digital Output at
Alarm
Sets the digital output status at
alarm operation.
Hold previous
value
Alarm Output Delay
Retards output from the alarm
terminal.
ON
Digit Number of
Measurement Value
Sets the display digits number
of measurement value on
compact programmable display.
5 digits
Analog Output at
Data Unfixed
Sets the analog output status at
data unfixed.
-10.800[V]
C
om
m
on
S
et
ti
ng
Sampling Cycle
Sets the sampling cycle for
measurement.
40µs
Terminal Input
Control
Sets that two sensor heads can
be operated by one terminal input.
Independent
Chattering Prevention
for Terminal Input
Prevents chattering of terminal
input.
ON1
Judgment Output Off
Delay
Delays the timing of switching ON
to OFF of the judgment output.
OFF
Interference
Prevention
Prevents interference between
2 sensor heads.
OFF
S
y
s
tem
S
et
ti
ng
Display Update Cycle
of Measurement Value
Sets the update cycle of
measurement value display.
Standard
Change Indication
Unit
Changes the indication unit of
the measurement value on
compact programmable display.
mm unit
Copy Output Setting
Copies the setting contents of “OUT Setting”
between memories.
X
Priority Setting of
Memory Change
Sets the terminals and commands.
Memory Change
Changes memory for saving the setting contents.
Memory Copy
Copies the saved contents in a memory to
another memory.
X
Initialization
Initializes the memory settings in current using.
X
Initialize All Memory Initializes all memory settings.
Save
Saves all memory settings.
X
Communication:
COM Port
Sets RS-232C communication.
Baud Rate
Sets the communication speed.
115200bps
Data Length
Sets the number of bits of data.
8bit
Parity
Sets the parity.
None
*Memory Change
: Maximum 16 settings can be saved by performing memory change.
X
: Settings cannot be changed by performing memory change.
:Settings are saved as common settings of all memories. Settings per each memory
cannot be executed.
Summary of Contents for HL-C2 Series
Page 32: ...Preface 30 MEMO ...
Page 50: ...Chapter 1 Prior to Use 1 18 1 MEMO ...
Page 65: ...Chapter 3 Programmable Display Operation 3 5 3 MEMO ...
Page 164: ...Chapter 4 Explanation of Functions 4 90 4 MEMO ...
Page 191: ...6 1 6 6 Maintenance and Inspection 6 1 Maintenance 6 2 6 2 Inspection 6 2 ...
Page 200: ...Chapter 7 Troubleshooting 7 8 7 MEMO ...
Page 250: ...Chapter 8 Specifications 8 50 8 50mm type Unit mm 85mm type Unit mm ...
Page 252: ...Chapter 8 Specifications 8 52 8 8mm type Unit mm 15mm type Unit mm ...
Page 270: ...Chapter 8 Specifications 8 70 8 MEMO ...
Page 271: ...1 Apx Appendix 1 Index 2 ...
Page 275: ...Appendix 5 Apx MEMO ...
Page 277: ......