Chapter 1 Prior to Use
1-15
1
1-4
Connection
1-4-1
Connection Method of Power Supply
♦
Connect 24VDC power supply wiring with
“24V”
and
“0V”
terminals of the terminal 3.
♦
Use twisted wires to minimize the effect of noise.
Rated Voltage
24VDC
Tolerance Voltage
Variation Range
21.6 to 26.4VDC
Consumption
Current
One sensor head: approx. 0.45A
Two sensor heads: approx. 0.6A
Incoming Current
8A or less
1-4-2
Connection Method of Terminal Block
The controller has three terminal blocks.
■ Model Number of Terminal Blocks
The terminal blocks are detachable from the controller and fixed with
screws. Use the tools and electric wire in the below list.
Terminal Block
Socket
Manufacturer
Type
PHOENIX CONTACT Ltd
MC1.5/16-ST-3.5
(Color:Black)
MC1.5/11-ST-3.5
(Color:Black)
Tightening Tool
Flathead Screwdriver
Tightening Torque
Blade Width: 0.4 X 2.5
0.22 to 0.25N·m
Adaptable
Electric Wire
(Stranded Wire)
Size
Cross-section Area
AWG#24 to 15
0.5 to 1.5mm
2
■ Wiring Method
24VDC
I/O Terminal Block
Analog Output/Laser Output Terminal Block
I/O Terminal Block
Summary of Contents for HL-C2 Series
Page 32: ...Preface 30 MEMO ...
Page 50: ...Chapter 1 Prior to Use 1 18 1 MEMO ...
Page 65: ...Chapter 3 Programmable Display Operation 3 5 3 MEMO ...
Page 164: ...Chapter 4 Explanation of Functions 4 90 4 MEMO ...
Page 191: ...6 1 6 6 Maintenance and Inspection 6 1 Maintenance 6 2 6 2 Inspection 6 2 ...
Page 200: ...Chapter 7 Troubleshooting 7 8 7 MEMO ...
Page 250: ...Chapter 8 Specifications 8 50 8 50mm type Unit mm 85mm type Unit mm ...
Page 252: ...Chapter 8 Specifications 8 52 8 8mm type Unit mm 15mm type Unit mm ...
Page 270: ...Chapter 8 Specifications 8 70 8 MEMO ...
Page 271: ...1 Apx Appendix 1 Index 2 ...
Page 275: ...Appendix 5 Apx MEMO ...
Page 277: ......