Chapter 4 Explanation of Functions
4-56
4
■ Chattering Prevention of Terminal Input
This function can prevent the chattering of the terminal input.
This function is used to prevent chattering for terminal input using the relay
contact or switch contact. The below list shows three settings of the function.
Setting
Function
OFF
Continuous input of longer than 50µs
ON1
Continuous input of longer than 20ms
ON2
Continuous input of longer than 100ms
Only “ON2” is used for the laser emission stop input, remote interlock input, and
memory change input to prevent misoperation.
● How to use
1
Display the “Chattering Prev for Term I/P”
screen.
2
Touch the “Chattering Prevention for
Terminal Input” key to select the setting.
The display is changed as below each time the
key is touched.
Status at chattering
prevented
“ON” shorter than
setting time
Terminal input status
ON
OFF
“ON” longer than
setting time
ON
OFF
“ON” longer than
setting time
When acted in level, the chattering
prevention functions while input is
OFF.
OFF
ON1
ON2
Summary of Contents for HL-C2 Series
Page 32: ...Preface 30 MEMO ...
Page 50: ...Chapter 1 Prior to Use 1 18 1 MEMO ...
Page 65: ...Chapter 3 Programmable Display Operation 3 5 3 MEMO ...
Page 164: ...Chapter 4 Explanation of Functions 4 90 4 MEMO ...
Page 191: ...6 1 6 6 Maintenance and Inspection 6 1 Maintenance 6 2 6 2 Inspection 6 2 ...
Page 200: ...Chapter 7 Troubleshooting 7 8 7 MEMO ...
Page 250: ...Chapter 8 Specifications 8 50 8 50mm type Unit mm 85mm type Unit mm ...
Page 252: ...Chapter 8 Specifications 8 52 8 8mm type Unit mm 15mm type Unit mm ...
Page 270: ...Chapter 8 Specifications 8 70 8 MEMO ...
Page 271: ...1 Apx Appendix 1 Index 2 ...
Page 275: ...Appendix 5 Apx MEMO ...
Page 277: ......