Chapter 8 Specifications
8-2
8
8-1
Controller Specifications
● RS-232C type
Model No.
HL-C2C(E)
HL-C2C(E)-P
Supply voltage
24VDC ±10% Including ripple 0.5V (P-P)
Current
consumption
Approx. 500mA at 2 sensor heads connected
Approx. 350mA at 1 sensor head connected
(Approx. 100mA is additionally required when the compact programmable display is connected.)
Sampling cycle
10µs, 20µs, 40µs, 100µs, 200µs, 400µs, 1ms, 2ms
Analog
output
Voltage
*1
Voltage output scale: -5 to +5V/F.S (initial value)
Output range during normal status: -10.0 to +10.0V
Output at abnormal status: -10.8V or +10.8V
Resolution: 2mV, Linearity: ±0.05% F.S.
Max. 2mA, output impeda
nce 50Ω, Response delay time: Approx. 1.5µs/V
Current
*2
Current output scale: 4 to 20mA/F.S (initial value)
Output range during normal status: 2 to 24mA
Output at abnormal status: 1mA or 25mA
Resolution: 3mA, Linearity ±0.05% F.S.
Load impedance: 250Ωmax., Response delay time: Approx. 10
µs
Alarm output
NPN transistor open collector
Maximum in-flow current: 100mA
Applied voltage: 3 to 30VDC
(ALARM output to Common(-))
Residual voltage: 1V or less
(at in-flow current of 100mA)
Leak current : 0.05mA or less
PNP transistor open collector
Maximum out-flow current: 100mA
Applied voltage: 3 to 30VDC
(ALARM output to +V)
Residual voltage: 1V or less
(at out-flow current of 100mA)
Leak current : 0.05mA or less
Output operation
Open when the output is ON (Light intensity is insufficient).
Short circuit protection
Incorporated (Auto-reset)
Judgment output
(HI, GO, LO
)
NPN transistor open collector
Maximum in-flow current: 100mA
Applied voltage: 3 to 30VDC
(Judgment output to Common(-))
Residual voltage: 1V or less
(at in-flow current of 100mA)
Leak current : 0.05mA or less
PNP transistor open collector
Maximum out-flow current: 100mA
Applied voltage: 3 to 30VDC
(Judgment output to +V)
Residual voltage: 1V or less
(at out-flow current of 100mA)
Leak current : 0.05mA or less
Output operation
Open when the output is ON(output operates).
Short circuit protection
Incorporated
(Auto-reset)
Strobe output
NPN transistor open collector
Maximum in-flow current: 100mA
Applied voltage: 3 to 30VDC
(Strobe output to Common(-))
Residual voltage: 1V or less
(at in-flow current of 100mA)
Leak current : 0.05mA or less
PNP transistor open collector
Maximum out-flow current: 100mA
Applied voltage: 3 to 30VDC
(Strobe output to +V)
Residual voltage: 1V or less
(at out-flow current of 100mA)
Leak current : 0.05mA or less
Output operation
Open when the output is ON(data is determined).
Short circuit protection
Incorporated (Auto-reset)
Summary of Contents for HL-C2 Series
Page 32: ...Preface 30 MEMO ...
Page 50: ...Chapter 1 Prior to Use 1 18 1 MEMO ...
Page 65: ...Chapter 3 Programmable Display Operation 3 5 3 MEMO ...
Page 164: ...Chapter 4 Explanation of Functions 4 90 4 MEMO ...
Page 191: ...6 1 6 6 Maintenance and Inspection 6 1 Maintenance 6 2 6 2 Inspection 6 2 ...
Page 200: ...Chapter 7 Troubleshooting 7 8 7 MEMO ...
Page 250: ...Chapter 8 Specifications 8 50 8 50mm type Unit mm 85mm type Unit mm ...
Page 252: ...Chapter 8 Specifications 8 52 8 8mm type Unit mm 15mm type Unit mm ...
Page 270: ...Chapter 8 Specifications 8 70 8 MEMO ...
Page 271: ...1 Apx Appendix 1 Index 2 ...
Page 275: ...Appendix 5 Apx MEMO ...
Page 277: ......