4-4-3
Memory Save and Terminal Setting
The setting contents for each function can be stored in 16 different patterns
in the controller memory.
This function stores the measurement or judgment conditions for each
measurement object respectively, so without re-inputting of various function
setting, the condition change can be performed only by changing the memory No.
“Memory change” can be executed by “Compact Programmable display” or
“External Terminal Input (M0 to M3)”.
■ Storable Functions in Memory
The function settings which can be stored in the memory are divided into two types.
One is the function which can be stored in each specified memory No., and another
is the function which can be stored as common setting value among all memories.
For the detail of the above two type storable functions, refer to
“4-3 Function
List & Initial Values”
.
■ Memory Change Procedure by External Input Terminal
1
Select Memory No. to be stored.
For setting by compact programmable display, refer to
“4-3-4 System
Setting” – “Memory Change”
.
2
After selecting memory No., input the setting value for each function.
For memory changeable functions, refer to
“4-3 Function List & Initial
Values”.
3
Set “Terminal” at “Priority Setting of Memory Change”.
For “Priority Setting of Memory Change”, refer to
“4-3-4 System Setting”
– “Priority Setting of Memory Change”
.
4
Execute all memory save.
If not doing so, “Terminal” cannot be set.
For “Save” function, refer to
“4-3-4 System Setting” – “Save”.
5
Set the memory No. to be used to the external terminal input (M0 - M3).
*The setting can be input by manually on the compact programmable display,
or by the command of RS-232C and USB communication control, or
Intelligent Monitor AiM.
With the above five steps, the memory No. change can be performed by the
external input terminal.
Summary of Contents for HL-C2 Series
Page 32: ...Preface 30 MEMO ...
Page 50: ...Chapter 1 Prior to Use 1 18 1 MEMO ...
Page 65: ...Chapter 3 Programmable Display Operation 3 5 3 MEMO ...
Page 164: ...Chapter 4 Explanation of Functions 4 90 4 MEMO ...
Page 191: ...6 1 6 6 Maintenance and Inspection 6 1 Maintenance 6 2 6 2 Inspection 6 2 ...
Page 200: ...Chapter 7 Troubleshooting 7 8 7 MEMO ...
Page 250: ...Chapter 8 Specifications 8 50 8 50mm type Unit mm 85mm type Unit mm ...
Page 252: ...Chapter 8 Specifications 8 52 8 8mm type Unit mm 15mm type Unit mm ...
Page 270: ...Chapter 8 Specifications 8 70 8 MEMO ...
Page 271: ...1 Apx Appendix 1 Index 2 ...
Page 275: ...Appendix 5 Apx MEMO ...
Page 277: ......