Chapter 8 Specifications
8-6
8
HL-C21C(E)
HL-C21C(E)-P
Remote interlock
input
Laser emission is delayed when
connected to Common (-).
Laser emission stop at open
Laser emission is delayed when
connected to IL (+).
Laser emission stop at open
Laser control input
Laser emission is stopped when
connected to Common (-).
Laser is emitted immediately after
opened.
Laser emission is stopped when
connected to external power (+).
Laser is emitted immediately after
opened.
Applied voltage: 10.8 to 30VDC
(Leak current: 0.1mA or less)
Zero set input
Zero set is ON when connected with
Common (-).
Zero set turns to OFF after
continuously connected to Common
(-) for one second.
Zero set is ON when connected with
external power (+).
Zero set turns to OFF after
continuously connected to external
power (+) for one second.
Applied voltage: 10.8 to 30VDC
(Leak current: 0.1mA or less)
Timing input
ON at/during connection to Common
(-) (depending on analysis mode)
ON at/during connection to external
power (+) (depending on analysis mode)
Applied voltage: 10.8 to 30VDC
(Leak current: 0.1mA or less)
Reset input
Reset is done when connected to
Common (-).
Reset is done when connected to
external power (+).
Applied voltage: 10.8 to 30VDC
(Leak current: 0.1mA or less)
Memory change input
Memory is specified when connected
to Common (-).
Memory is specified when
connected to external power (+).
Applied voltage: 10.8 to 30VDC
(Leak current: 0.1mA or less)
Ethernet interface
IEEE 802.3u,100BASE-TX/10BASE-T Connector shape: RJ45
USB interface
USB 2.0 Full-speed (USB 1.1 compatible) compliant
Connecting sensor head
Maximum 2 sensor heads with connection compatibility
Setting/data display
Compact programmable display
Indi
c
at
o
r
Power
Green LED: ON at power on.
Sensor head A
Laser radiation
Green LED: ON during or immediately before laser emission of sensor head A.
Sensor head B
Laser radiation
Green LED: ON during or immediately before laser emission of sensor head B.
Alarm 1
Red LED: ON when OUT1 can not be measured due to insufficient amount of light
Alarm 2
Red LED: ON when OUT2 can not be measured due to insufficient amount of light
Protective structure
IP30
Pollution Degree
2
Insulation Resistance 20M ohms or more by 500V dc megger (between live parts and enclosure or F.G.)
Die
le
c
tr
ic
W
it
hs
tan
d
Commercial
Frequency
AC500V for 1min. (between live parts and enclosure or F.G.)
Impulse
+/– 1000V 1.2/50
μs
(between power supply, input/output, and F.G.)
Vibration resistance
Endurance: 10 to 55Hz (cycle: 1 minute), Resistant amplitude of vibration: 0.75mm,
in X, Y, and Z directions for 30 minutes
Shock resistance
196m/s
2
in X, Y, and Z directions for 3 times
Ambient temperature 0 to +50°C (No dew condensation or icing allowed) At storage: –20 to +70°C
Summary of Contents for HL-C2 Series
Page 32: ...Preface 30 MEMO ...
Page 50: ...Chapter 1 Prior to Use 1 18 1 MEMO ...
Page 65: ...Chapter 3 Programmable Display Operation 3 5 3 MEMO ...
Page 164: ...Chapter 4 Explanation of Functions 4 90 4 MEMO ...
Page 191: ...6 1 6 6 Maintenance and Inspection 6 1 Maintenance 6 2 6 2 Inspection 6 2 ...
Page 200: ...Chapter 7 Troubleshooting 7 8 7 MEMO ...
Page 250: ...Chapter 8 Specifications 8 50 8 50mm type Unit mm 85mm type Unit mm ...
Page 252: ...Chapter 8 Specifications 8 52 8 8mm type Unit mm 15mm type Unit mm ...
Page 270: ...Chapter 8 Specifications 8 70 8 MEMO ...
Page 271: ...1 Apx Appendix 1 Index 2 ...
Page 275: ...Appendix 5 Apx MEMO ...
Page 277: ......