15-13
WR903 FP0R
Relay No.
Name
Description
R9030
Not used
R9031
Not used
R9032
COM port
communication mode
flag
-
Turns on when the general-purpose communication function
is being used
-
Goes off when the MEWTOCOL-COM or the PLC link
function is being used.
R9033
Print instruction
execution flag
Off: Printing is not executed.
On: Execution is in progress.
R9034
RUN overwrite
complete flag
Goes on for ony the first scan following completion of a rewrite
during the RUN operation.
R9035
Not used
R9036
Not used
R9037
COM port
communication error
flag
-
Goes on is a transmission error occurs during data
communication.
-
Goes off when a request is made to send data, using the
F159 (MTRN) instruction.
R9038
COM port reception
done flag during
general purpose
communication
-
Turns on when the terminator is received during general -
purpose serial communication.
R9039
COM port
transmission done
flag during general-
purpose serial
communication
-
Goes on when transmission has been completed in general-
purpose serial communication.
-
Goes off when transmission is requested in general-purpose
serial communication.
R903A
Not used
R903B
Not used
R903C
Not used
R903D
Not used
R903E
TOOL port reception
done flag during
general purpose
communication
-
Turns on the terminator is received during general -purpose
serial communication.
R903F
TOOL port
transmission done
flag during general-
purpose serial
communication
-
Goes on when transmission has been completed in general-
purpose serial communication.
-
Goes off when transmission is requested in general-purpose
serial communication.
A: Available, N/A: Not available
Note) R9030 to R9030F can be changed during 1 scan.
Summary of Contents for FP0R Series
Page 1: ......
Page 6: ...iv ...
Page 14: ...xii ...
Page 15: ...Chapter 1 Functions and Restrictions of the Unit ...
Page 24: ...1 10 ...
Page 25: ...Chapter 2 Specifications and Functions of Control Unit ...
Page 38: ...2 14 ...
Page 39: ...Chapter 3 Expansion ...
Page 45: ...3 7 3 4 Terminal layout diagram Model No Terminal layout diagrams E8RS E8RM E16RS E16RM E8YRS ...
Page 48: ...3 10 ...
Page 49: ...Chapter 4 I O Allocation ...
Page 53: ...Chapter 5 Installation and Wiring ...
Page 73: ...Chapter 6 Preparation of USB Port ...
Page 77: ...6 5 5 Click Finish on the following screen to be displayed ...
Page 79: ...6 7 4 Double click on FP0R 5 Click Update Driver ...
Page 84: ...6 12 ...
Page 85: ...Chapter 7 Communication ...
Page 139: ...7 55 Sample program For Type II Use a program as below to directly specify a MODBUS address ...
Page 141: ...Chapter 8 High speed Counter Pulse Output and PWM Output Functions ...
Page 142: ...8 2 ...
Page 199: ...Chapter 9 Security Functions ...
Page 211: ...Chapter 10 Other Functions ...
Page 217: ...Chapter 11 Self Diagnostic and Troubleshooting ...
Page 227: ...Chapter 12 Precautions During Programming ...
Page 242: ...12 16 ...
Page 243: ...Chapter 13 Specifications ...
Page 254: ...13 12 ...
Page 255: ...Chapter 14 Dimensions and Others ...
Page 262: ...14 8 ...
Page 263: ...Chapter 15 Appendix ...
Page 344: ...15 82 15 7 ASCII Codes ...
Page 346: ......
Page 347: ......
Page 348: ......