15-6
FP0R
No.
Name
Default value
Descriptions
C
on
tr
ol
le
r i
np
ut
s
et
tin
gs
1
Hi
gh
-s
pe
ed
c
ou
nte
r
400
High-speed
counter
operation
mode
settings (X0
to X2)
CH0:
Do not set input
X0 as high-speed
counter
CH0
Do not set input X0 as high-speed counter.
Two-phase input (X0, X1)
Two-phase input (X0, X1), Reset input (X2)
Incremental input (X0)
Incremental input (X0), Reset input (X2)
Decremental input (X0)
Decremental input (X0), Reset input (X2)
Individual input (X0, X1)
Individual input (X0, X1), Reset input (X2)
Incremental/decremental control input (X0, X1)
Incremental/decremental control input (X0, X1),
Reset input (X2)
CH1:
Do not set input
X1 as high-speed
counter
CH1
Do not set input X1 as high-speed counter.
Incremental input (X1)
Incremental inptu (X1), Reset input (X2)
Decremental input (X1)
Decremental input (X1), Reset input (X2)
400
High-speed
counter
operation
mode
settings (X3
to X5)
CH2:
Do not set input
X3 as high-speed
counter
CH2
Do not set input X3 as high-speed counter.
Two-phase input (X3, X4)
Two-phase input (X3, X4), Reset input (X5)
Incremental input (X3)
Incremental input (X3), Reset input (X5)
Decremental input (X5)
Decremental input (X5), Reset input (X5)
Individual input (X3, X4)
Individual input (X3, X4), Reset input (X5)
Incremental/decremental control (X3, X4)
Incremental/decremental control (X3, X4),
Reset input (X5)
CH3:
Does not set
input X4 as high-
speed counter
CH3
Does not set input X4 as high-speed counter.
Incremental input (X4)
Incremental input (X4), Reset input (X5)
Decremental input (X4)
Decremental input (X4), Reset input (X5)
C
on
tr
ol
le
r i
np
ut
se
tti
ng
s 2
Hi
gh
-s
pe
ed
c
ou
nte
r
401
High-speed
counter/
pulse output
settings
(X6 to X7)
CH4:
Do not set input
X6 as high-speed
counter
CH4
Do not set input X6 as high-speed counter.
Incremental input (X6)
Decremental input (X6)
Two-phase input (X6, X7)
Individual input (X6, X7)
Incremental/decremental control input (X6, X7)
CH5:
Do not set input
X7 as high-speed
counter
CH5
Do not set input X7 as high-speed counter.
Incremental input (X7)
Decremental input (X7)
Note1) If the operation mode is set to Two-phase, incremental/decremental, or incremental/decremental
control, the setting for CH1 or CH3 is invalid in system register 400 and the setting for CH5 is
invalid in system register 401.
Note2) If reset input settings overlap, the CH1 setting takes precedence in system register 400 and the
CH3 setting takes precedence in system register 401.
Note3) If system register 400 to 403 have been set simultaneously for the same input relay, the follwing
precedence order is effective: [High-speed counter]
→
[Pulse catch]
→
[Interrupt input].
<Example>
When the high-speed counter is being used in the addition input mode, even if input X0 is
specified as an interrupt input or as pulse catch input, those settings are invalid, and X0
functions as counter input for the high-speed counter.
Summary of Contents for FP0R Series
Page 1: ......
Page 6: ...iv ...
Page 14: ...xii ...
Page 15: ...Chapter 1 Functions and Restrictions of the Unit ...
Page 24: ...1 10 ...
Page 25: ...Chapter 2 Specifications and Functions of Control Unit ...
Page 38: ...2 14 ...
Page 39: ...Chapter 3 Expansion ...
Page 45: ...3 7 3 4 Terminal layout diagram Model No Terminal layout diagrams E8RS E8RM E16RS E16RM E8YRS ...
Page 48: ...3 10 ...
Page 49: ...Chapter 4 I O Allocation ...
Page 53: ...Chapter 5 Installation and Wiring ...
Page 73: ...Chapter 6 Preparation of USB Port ...
Page 77: ...6 5 5 Click Finish on the following screen to be displayed ...
Page 79: ...6 7 4 Double click on FP0R 5 Click Update Driver ...
Page 84: ...6 12 ...
Page 85: ...Chapter 7 Communication ...
Page 139: ...7 55 Sample program For Type II Use a program as below to directly specify a MODBUS address ...
Page 141: ...Chapter 8 High speed Counter Pulse Output and PWM Output Functions ...
Page 142: ...8 2 ...
Page 199: ...Chapter 9 Security Functions ...
Page 211: ...Chapter 10 Other Functions ...
Page 217: ...Chapter 11 Self Diagnostic and Troubleshooting ...
Page 227: ...Chapter 12 Precautions During Programming ...
Page 242: ...12 16 ...
Page 243: ...Chapter 13 Specifications ...
Page 254: ...13 12 ...
Page 255: ...Chapter 14 Dimensions and Others ...
Page 262: ...14 8 ...
Page 263: ...Chapter 15 Appendix ...
Page 344: ...15 82 15 7 ASCII Codes ...
Page 346: ......
Page 347: ......
Page 348: ......