3-90
Chapter 3 Troubleshooting
015-381 Platen AGC CH2 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH2 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-382 Platen AGC CH3 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH3 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-383 Platen AGC CH4 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH4 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-384 Platen AGC CH5 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH5 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-385 Platen AGC CH6 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH6 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-386 Platen AOC CH1 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH1 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-387 Platen AOC CH2 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AOC CH2 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-388 Platen AOC CH3 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AOC CH3 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
Summary of Contents for DP-C321
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......